Panel Install manual

Table Of Contents

REC Installation Manual - REC Panels - UL 6
Rev L  . Ref: PMIM
Fig. : Clamping of N-Peak panels on rails parallel to short side of module
INSTALLATION OF REC NPEAK PANELS
MOUNTING REC NPEAK PANELS WITH CONTINUOUS RAILS PARALLEL TO SHORT SIDE OF THE PANEL
A continuous rail (or other support structure) spans the complete underside of the panel.
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be rated to that load (fig. ).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
9.8 in [250 mm]
9.8 in [250 mm]
4 in [100 mm]
4 in [100 mm]
9.8 in [250 mm]9.8 in [250 mm]
4 in [100 mm]4 in [100 mm]
13.4 in [340 mm]
20.5 in [520 mm]
25.6 in [650 mm]
16.5 in [420 mm]
0
0
0
0
0
8.2 in [208 mm]
13.4 in [340 mm]
20.5 in [520 mm]
25.6 in [650 mm]
16.5 in [420 mm]
0
8.2 in [208 mm]
Rail positioning
Rail positioning
Legend
Clearance Gap
Clamping zone
.  .in mm) .  . in mm) >. in (>mm) <. in (<mm)
Test Load
(Design Load)
Test Load
(Design Load)
Test Load
(Design Load)
Test Load
(Design Load)
  . in
  mm)
X
+Pa /  Pa *
(+Pa / Pa)
+ Pa /  Pa
(+ Pa / Pa)
X
.  . in
  mm)
+ Pa /  Pa *
(+ Pa / Pa)
+ Pa / Pa
(+Pa /  Pa)
+ Pa / Pa
(+ Pa / Pa)
X
.  . in
  mm)
+ Pa /  Pa *
(+ Pa / Pa)
+ Pa / Pa
(+ Pa /  Pa)
+ Pa / Pa
(+ Pa / Pa)
X
. - . in
  mm)
+Pa /  Pa *
(+Pa / Pa)
+ Pa / Pa
(+Pa /  Pa)
+ Pa / Pa
(+ Pa / Pa)
X
. - . in
   mm)
+ Pa /  Pa
(+ Pa / Pa)
+ Pa /  Pa
(+ Pa / Pa)
+ Pa /  Pa
(+ Pa / Pa)
X
   in
   mm)
X
+Pa /  Pa *
(+Pa / Pa)
+ Pa /  Pa *
(+ Pa / Pa)
X
 - . in
   mm)
X
+ Pa /  Pa *
(+ Pa / Pa)
+ Pa /  Pa
(+ Pa / Pa)
X
Once a module is secured in each of the  zones (fig. ), additional clamps, i.e., ≥ may be freely located on panel frame without affecting
the warranty. Loads marked with a
* were not certified as part of IEC / UL  testing; these have been evaluated by REC’s
internal testing process.
Long Side Mounting
Short Side
Mounting
Rail position
Rail position