REC N-PEAK Installation & Maintenance

REC Installation Manual - NPeak - IEC  /
Rev B  . Ref: NE

Ref: NE-Rev- B .
28 [1.1]
1675±2.5 [65.94 ±0.1]
910 [35.8]
382.5 [15.05]
956 [37.64]
997±2.5 [39.25 ±0.1]
17 [0.7]
45 [1.5]
1000 [39]
1200 [47]
Scale: 1:1.57
11±0.2
[0.43 ±0.8]
6.6±0.2 [0.26 ±0.08]
20.5±0.5
[0.78 ±0.08]
30 [1.18]
22.5 [0.9]
600 ±1 [23.6 ±0.04]
GR
GR
GR
GR
CERTIFICATE BBA 0148
MCS
PANEL CHARACTERISTICS
TECHNICAL PROPERTIES: REC NPEAK SERIES
Fig. : Panel dimensions: REC N-Peak Series
Specifications subject to change without notice.
WARRANTY
IEC , IEC  & UL ; MCS ,
IEC , IEC , IEC , IEC 
ISO : , ISO : , OHSAS : 
 year product warranty
 year linear power output warranty, maximum
degression in performance of . p.a., giving
 at end of year .
See warranty conditions for further details.
GENERAL DATA
Cell type:  half-cut mono c-Si n-type cells
 strings of  cells in series
Glass: . mm solar glass with
anti-reflection surface treatment
Backsheet: Highly resistant polymeric
construction
Frame: Anodized aluminum (black)
Junction box: -part,  bypass diodes, IP rated
in accordance with IEC 
Cable: mm solar cable, . m + . m
in accordance with EN 
Connectors: Stäubli MC PVKBT/KST ( mm)
in accordance with IEC 
IP only when connected
Origin: Made in Singapore
LOW LIGHT BEHAVIOUR
TEMPERATURE RATINGS
*
MAXIMUM RATINGS
MECHANICAL DATA
Dimensions:  x  x  mm
Area: . m
Weight:  kg
Operational temperature:  ... +°C
Maximum system voltage:  V
Design load (+): snow  Pa ( kg/m)
+
Maximum test load (+):  Pa ( kg/m)
*
Design load (-): wind  Pa ( kg/m)
+
Maximum test load (-):  Pa ( kg/m)
*
Max series fuse rating:  A
Max reverse current:  A
+
Calculated using a safety factor of .
* See installation manual for mounting instructions
ELECTRICAL DATA  STC
Product code
*
: RECxxxNP
Nominal Power - P
MPP
(Wp)     
Wa Class Sorting - (W) /+ /+ /+ /+ /+
Nominal Power Voltage - V
MPP
(V) . . . . .
Nominal Power Current - I
MPP
(A) . . . . .
Open Circuit Voltage - V
OC
(V) . . . . .
Short Circuit Current - I
SC
(A) . . . . .
Panel Efficiency () . . . . .
Values at standard test conditions (STC: air mass AM ., irradiance  W/m, temperature °C), based on a production spread with a
tolerance of V
OC
& I
SC
± within one wa class. * Where xxx indicates the nominal power class (P
MPP
) at STC above.
ELECTRICAL DATA  NMOT
Product code
*
: RECxxxNP
Nominal Power - P
MPP
(Wp)
    
Nominal Power Voltage - V
MPP
(V)
. . . . .
Nominal Power Current - I
MPP
(A)
. . . . .
Open Circuit Voltage - V
OC
(V)
. . . . .
Short Circuit Current - I
SC
(A)
. . . . .
Nominal module operating temperature (NMOT: air mass AM ., irradiance  W/m, temperature °C, windspeed  m/s).
* Where xxx indicates the nominal power class (P
MPP
) at STC above.
CERTIFICATIONS
Measurements in mm [in]
Nominal Module Operating Temperature: °C°C)
Temperature coefficient of P
MPP
: . /°C
Temperature coefficient of V
OC
: . /°C
Temperature coefficient of I
SC
: . /°C
* The temperature coefficients stated are linear values
Rel. Efficiency ()
take-e-way WEEE-compliant recycling scheme
100 200 300 400 500 600 700 800 900 1000
85
90
95
100
105
Irradiance (W/m)
Typical low irradiance performance of panel at STC: