Specifications

TC35 / TC37 Hardware Interface Description
TC35_37_HD_02_V03.10 - Released Page 71 of 92 21.12.2001
Table 24: Stress characteristics of the GSC antenna connector
Parameter Specification
Connector durability 100 cycles of mating and withdrawal with a jig at 12 cycles/minute
maximum
Engage force 30N max
Disengage force 3N min, 30N max
Angle of engagement 15 degree max
Mechanical stress to connector
Stress to the housing:
Stress to outer sleeve:
Cable pull strength:
See Figure 36 for details
A and B: 4.9N max.
C: 2.94N max and D: 1.96N max
E: 4.9N max
Figure 36: Maximum mechanical stress to the connector
The following figure illustrates the engagement/disengagement tool type P/N M22001
recommended by MuRata and provides instructions for proper use.
Figure 37: How to use MuRata tool