Spec Sheet 1
9
OPERATING INSTRUCTIONS
If your gas log set is operated by the fi replace valve:
1. Lay a lighted long-stem match on the surface of the glass/gems near the gas inlet (do not hold the
match in your hand) or use a lighted long-necked butane lighter (Fig. 9-1).
2. Slowly turn the fi replace remote valve to the ON position. Your burner should light.
3. If the burner does not light before the match goes out,
immediately turn the valve to the OFF position.
4. Wait approximately fi ve (5) minutes to clear out any gas,
and repeat steps 1-3 above.
5. If your burner fails to light again, turn the valve to the OFF
position and contact your dealer or gas supplier.
6. To extinguish your gas burner, turn the valve to the OFF
position. Be sure the valve is turned fully off to avoid any
gas leakage.
If your burner is operated by a pilot kit:
1. Carefully follow the lighting instructions supplied with your pilot kit for the steps to ignite the burner.
Before operating your gas log set:
1. Be sure your fi replace is free from fl ammable liquids or combustible materials.
2. Be sure your damper is open.
3. Smell all around the gas log set for the odor of escaping gas. IF YOU SMELL GAS, FOLLOW THE
INSTRUCTIONS ON P. 1.
Fig. 9-1
Apply match - then turn on gas