WARNING
If you do not follow these instructions exactly, a fi re or explosion may result, causing property
damage, personal injury, or loss of life.
LIGHTING INSTRUCTIONS - SERIES 15 VALVE
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional service technician
to inspect the appliance and to replace any part of the control system and any gas control that has been underwater.
Ignition control knob - positions
OFF IGNITION PILOT ON
Fig. 23-1
LIGHTING THE PILOT
1. Turn the ignition control knob (Fig. 23-1) on the burner
control valve assembly (the side of burner pan)
counterclockwise so that the narrowing part of the knob
moves from the OFF position, slightly toward IGN, until
reaching the stop.
2. Press the ignition control knob in and hold in for fi ve (5)
seconds (only pilot gas will fl ow).
3. Continue pressing in while turning the ignition control
knob further counterclockwise toward the PILOT position
until you hear a click. The click is an indication that the
piezo igniter has been activated.
Note: If the spark from the piezo igniter does not light
the pilot, repeat steps 2 & 3 until the pilot lights.
4. Continue to hold the ignition control knob in the PILOT
position for 60 seconds after the pilot has been lit to allow
the thermocouple to detect the pilot fl ame. The pilot will
remain lit. If the pilot fails to light after several tries,
turn the ignition control knob to OFF and contact a
qualifi ed professional service technician.
IGNITING THE MAIN BURNER
1. When the pilot fl ame is stable, release the ignition control
knob and turn counterclockwise to the ON position to
enable the main burner.
2. Turn the flame-height control knob (Fig.
23-3) counterclockwise to the fully ON position
(Fig. 23-4) to ignite the burner at maximum BTUs. After
the main burner ignites, adjust the fl ame height as
indicated in the following section.
ADJUSTING THE FLAME HEIGHT
To adjust the fl ame, turn the fl ame-height control knob (Fig.
23-3) counterclockwise (toward ON) to increase the fl ame
height, or clockwise (toward OFF) to decrease the fl ame
height, until the fl ames have the desired characteristics.
Note: Turning the fl ame-height control knob to OFF will
turn off the burner. The pilot will remain lit. The
burner system can be relit by turning the fl ame-
height control knob toward ON.
SHUTTING DOWN
MAIN BURNER ONLY (pilot will remain lit):
Turn the fl ame-height control knob clockwise to OFF.
(The ignition control knob will remain in the ON position.)
BURNER AND PILOT (total shutdown):
If you do not plan on using your burner system for an
extended period (one week or more), you may extinguish
the pilot. This will conserve energy and save you money.
Turn the fl ame-height control knob clockwise to OFF and then
turn the igniter control knob clockwise to OFF.
Important: If you desire to turn the unit back on, wait a
minimum of one (1) minute before starting the
relight procedure. This allows the safety valve
to reset in preparation for relighting.
FOR YOUR SAFETY, READ BEFORE LIGHTING
Fig. 23-3
Ignition
control
knob
Flame-height
control knob
Flame-height control knob
Fig. 23-4
OFF ON
If this unit was shipped with a remote, or if a remote
was installed later, read and follow the separate remote
instructions to operate the burner remotely.
Fig. 23-2
Thermocouple
The Real Fyre burner system has a pilot. When starting the pilot, follow these instructions exactly.
BEFORE LIGHTING, smell all around the gas burner system area for gas. Be sure to smell next to the fl oor, as some gas
is heavier than air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON P. 1.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't
try to repair it. Call a qualifi ed professional service technician. Force or attempted repair may result in fi re or explosion.
Fig. 23-2
Thermocouple