Spec Sheet 1

14
INSTALLATION
The damper clamp with hex bolt (Fig. 14-1) is provided as a means to
prevent full closure of the damper blade. The clamp is easily attached to most
damper blades with pliers or a wrench, and must be permanently installed.
The clamp is designed to prevent accidental closure of the damper when
installed as illustrated (
Fig. 14-2 and Fig. 14-3). Should the clamp not fi t, or
fail to provide the permanent vent opening listed in the table found above,
have a permanent stop installed, remove the damper
blade, or have the damper cut to provide the minimum
permanent opening required.
Note: These are minimum damper opening
specifi cations. The damper must be completely
opened when operating this gas appliance to
achieve the best ventilation possible.
INSTALLING THE BURNER
The Real Fyre gas burner system must be installed by a qualifi ed professional service technician. Instructions
must be followed carefully to ensure proper performance and full benefi t from the gas burner system. Check to
be sure the burner system is designed and labeled for the type of gas (natural or propane gas) supplied
to the fi replace. Fireplace fl oor must be level, clean, and smooth.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and remove the cap, if attached (see Fig. 14-4).
CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall.
3. Attach the nut end of the fl ex connector (Item 4) to the adapter found on the valve or, if attached, on the
regulator behind the valve. Tighten securely.
4. Place the burner system into the fi replace so that it is centered and the open burner pan faces outward.
5. Be sure gas to the fi replace is off. Attach the large adapter end of the fl ex connector (Item 4) to the gas-supply
stub using a pipe compound resistant to all gases. Ensure adapter (and nut) are tightened securely. Ensure
the pan rests level on the fi replace oor after connection. Adjust the pan if necessary.
6. LEAK TEST: Turn on the fi replace gas supply, and test at all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present. Turn off the gas and tighten at all connections. Repeat
until no leaks are present. If a leak persists, turn off the gas supply and contact the local gas company or
dealer. NEVER USE A FLAME TO CHECK FOR LEAKS.
Turn off the gas supply prior to proceeding.
7. Place the heat shield over the regulator and/or valve.
Important: Heat shields must be in place during operation
of the gas burner system. Overheating of the
valve will cause shut down of the gas burner
system or other operating problems.
8. If this unit was shipped with a remote, read and follow the
separate remote instructions (packed with remote) for
complete remote installation.
Fig. 14-1
Damper clamp
Set screw
Fig. 14-2 Fig. 14-3
Open
Closed
4. Place the burner system into the fi replace so that it is centered.
Fig. 14-4
Gas supply
line stub
Gas line
cap