Maintenance
Once installed and operating properly, your Real-
Fyre gas log set requires very little maintenance.
You should inspect your log set and control annually
for the following:
1. Excessive Sooting - Some sooting of your log
set is normal and adds to the appearance of
burned wood. If sooting accumulates, you may
brush the soot off with a stiff brush. Do not use
water or soot cleaners to clean off the soot.
2. Settling of Ember Glow and Granules - Moisture
may cause the granules and ember glow in your
burner pan to settle and affect your burn. Using
a screwdriver or fl at blade knife, carefully
stir the granules and embers, loosening the
materials.
3. Debris around the control - Inspect the control
and pilot to be sure it is free of any dirt or debris.
Service
While some minor service conditions may
be handled by the owner of the log set, it is
recommended that a qualifi ed service technician be
called to service your gas log set and control should
service be required. The troubleshooting section of
these instructions serves as a guide for ensuring
optimum performance of your gas log set.
TECHNICAL DATA AND SPECIFICATION INFORMATION
TECHNICAL DATA AND SPECIFICATION INFORMATION
To adjust the fl ame pattern, take a long blade screwdriver or similar tool and stir the granules until the desired
pattern is achieved. DO NOT REMOVE GRANULES FROM THE BURNER PAN
OPERATING YOUR LOG SET - LIGHTING AND EXTINGUISHING
LIGHTING YOUR GAS LOG SET (NATURAL UNIT)
If your Real-Fyre gas log set is operated by the
fi replace valve:
1. Lay a lighted long-stem match on the surface of
the embers near the gas inlet (do not hold the
match in your hand) or use a lighted long-
necked butane lighter.
2. Slowly turn the fi replace remote valve to the
“ON” position. Your log set should light.
3. If the log set does not light before the match
goes out, immediately turn the valve “OFF”.
4. Wait approximately fi ve (5) minutes to clear out
any gas, and repeat steps 1-3 above. Smell for
gas including near the fl oor. If you smell gas,
stop and follow step B of the safety information on
page 10. If you don’t smell gas, go to next step.
5. If your log set fails to light again, turn off the valve
and contact your dealer or gas supplier.
6. To extinguish your Real-Fyre gas log set, simply
turn the valve to the “OFF” position. Be sure
the valve is turned completely off to avoid any gas
leakage.
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property
damage, personal injury or loss of life.
ON
OFF
Insert blade into sand and stir
granules in various places until
desired fl ame pattern is achieved.
Long bladed screwdriver
(or similar)
R
E
F
E
R
E
N
C
E