Owner`s manual
10
No. L-A2-17506
REV 3 - 0603021604
LIGHTING YOUR GAS LOG SET (PROPANE UNIT):
1. After you have fi nished checking for leaks, ensure that the unit is turned completely off by pushing in the
“ON/OFF” control knob and turning clockwise toward “OFF” until you reach a stop.
2. Turn the “ON/OFF” control knob counterclockwise to the “ON” position. DO NOT PUSH KNOB IN!
NOTE: You should not hear or smell any gas at this point.
3. Wait fi ve (5) minutes to clear out any gas. Smell for gas, including near the fl oor. If you smell gas, stop
and follow step B of the safety information above. If you don’t smell gas, go to next step.
4. LIGHTING INSTRUCTIONS
a. Press and hold in the electronic ignitor button. The ignitor will spark with a rapid clicking noise.
b. While holding in the electronic ignitor, push in the “ON/OFF” control knob to open the valve.
Burner will now ignite at the maximum BTU input.
c. Continue to hold knob for 10-15 seconds; this will allow the safety valve to activate and the main
burner to remain burning.
Turning Off Your Gas Log Set:
1. Push in the “ON/OFF” control knob and turn clockwise
toward “OFF” until you reach a stop (burner will
extinguish).
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property
damage, personal injury or loss of life.
A. BEFORE LIGHTING, smell all around the gas
log set area for gas. Be sure to smell next to the
fl oor because some gas is heavier than air and
will settle on the fl oor.
B. WHAT TO DO IF YOU SMELL GAS
• Open a window.
• Do not try to light the appliance.
• Do not touch any electrical switch, do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it. Call
a qualifi ed service technician. Force or attempted
repair may result in fi re or explosion.
D. Do not use the gas log set if any part has been
under water. Immediately call a qualifi ed service
technician to inspect the gas log set and to
replace any part of the control system and any
gas control which has been under water.
PIEZO IGNITOR
“ON/OFF”
CONTROL KNOB
Figure 18
OPERATING YOUR LOG SET - LIGHTING AND EXTINGUISHING
* We recommend that before you install your log set you familiarize yourself with the control valve layout. This will
help you to be confi dent operating the log set when fully installed (see Figure 18 below for typical control positions).