Spec Sheet 1

3
L-F2-119
REV 3 - 1809121400
SPECIFICATIONS AND REQUIREMENTS
WARNING: This appliance is for installation only in a:
1. Solid-fuel-burning masonry or UL-127
factory-built fi replace, or
2. Listed ventless fi rebox enclosure.
It has been designed certifi ed for these installations.
Exception: DO NOT install this appliance in a factory
built fi replace that includes instructions stating it has not
been tested or should not be used with unvented burner
systems.
Note: Installation in any other fi replace is prohibited and
will void any approvals and warranties.
Fireplace Dimensions
Fig. 3-1
This burner system is equipped with an Oxygen
Depletion Sensor (ODS) safety pilot system. The ODS
senses the amount of oxygen available in the room and
shuts the burner system off before the oxygen level
drops below 18%. The pilot can only be relit when fresh
air is available. This may require opening a window
or a door to another room or cracking the damper
open slightly.
This burner system has been certifi ed to two standards:
UNVENTED ROOM HEATER-ANSI Z21.11.2
VENTED DECORATIVE APPLIANCE-ANSI Z21.60
Check local or state codes to determine if vent-free
heaters are permitted in your locality before you
install this burner system as a vent-free appliance. If
not permitted, you may install and operate this burner
system as a vented appliance.
This unit may not be installed in a vented fi replace with
a chimney of less than 15 feet in height.
Observing minimum fi replace dimensions and centering
the appliance in the fi replace will ensure adequate
clearance for operation and servicing. It may be
necessary to disconnect the unit for some types of
service.
Any installation of this appliance is subject to minimum fi replace size requirements below:
DEPTH
HEIGHT
FR ONT
WIDTH OPENING
Rear
width
Height
Front
width opening
Depth
Minimum Permanent Chimney Vent Opening
in sq. in. (when used as a vented appliance)
Table 3-1 Factory built fi replaces*
Chimney
Height
18/20" 24/30"
15' 13 18
20' 11 15
25' 10 13
30' 10 12
*For masonry-built fi replaces, add 10 sq. in. to amount
shown.
Burner
Model
Minimum Fireplace Size (refer to Fig. 3-1) BTU Rating
Width
Depth Height
Nat. Gas L.P. Gas
Front Rear*
Low
Setting†
High
Setting
Low
Setting†
High
Setting
G19A-18/20 (18" log set) 24" 22" 14" 17" 27k 34k 23k 30k
G19A-24/30 (24" log set) 30" 24" 14" 17" 30k 40k 26k 36k
G19A-24/30 (30" log set) 34" 26" 14" 17" 30k 40k 26k 36k
* based on minimum depth
† Low Setting is only available on 01V &15 models
Specifi cation Value Qty.
Remote receiver battery type AA battery 4
12 and 15 Models remote transmitter battery type 12V battery 1
01V Models remote transmitter battery type 9V battery 1
Table 3-2 - Technical Data (if applicable)