This safety pilot system must be installed by a qualified professional service technician. Instructions
must be followed carefully when installing to ensure proper performance and full benefit from the
burner system and safety pilot system.
These instructions must be used as a supplement to the instructions supplied with the R.H. Peterson burner
system. Follow the burner system instructions and make adjustments as appropriate for the addition of a
safety pilot system. Use gas pipe sealing compound that is resistant to all gasses (or Teflon tape) and apply
to all male pipe connections. DO NOT apply pipe sealing compound to any flare connections. Make sure that
all connections are tight.
INSTALLATION
Fig. 7-1 Install pilot bracket
Burner pan
Fuel injector
or air mixer
Valve
Attach the valve to the
air mixer/fuel injector by
rotating the burner pan.
Fig. 7-2 Install valve
Install for 2V and
3V valves is the
same. 2V SHOWN.
Fig. 7-3 Proper valve orientation
Ensure pan rests
flat on floor
The valve system is shipped pre-assembled for easy
installation onto the burner pan. Perform installation with
care ensuring not to damage the pilot assembly, or the
wires that connect the components and heat shield.
Note: Installation is easier when done outside of the
fireplace.
PREPARATION
If the burner that the valve system is to be added to is
already installed; remove all decorative media, set aside to
be reinstalled later, and disconnect the flex connector and
adapter from the burner pan (using the instructions that
came with the original burner).
ELECTRICAL SETUP (if applicable)
A 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire
receptacle (not included) is required within the vicinity of
the fireplace to provide power to the unit. Power supply
cord is located on the rear of the control box. Your individual
installation may vary. Observe all local codes.
1. Wire the receptacle into the vicinity of the fireplace.
• Verify proper polarity of the receptacle.
• DO NOT TAMPER WITH THE EXTENSION CORD
OR THE UNIT POWER-SUPPLY CORD.
INSTALL PILOT MOUNTING BRACKET
CAUTION: Use only the pilot assembly pre-assembled
with this kit. Never substitute with an existing
pilot.
The pilot assembly comes with an L-shaped mounting
bracket.Remove the two phillips screws holding the bracket
in place, then use them to fasten the bracket to burner pan
(short side toward the back of the pan) using the pre-drilled
holes in the pan (see Fig. 7-1).
INSTALL THE VALVE
1. Apply gas pipe sealing compound (or Teflon tape) to the
male end of the fuel injector or air mixer on the burner.
2. Install the valve to the fuel injector or air mixer by
screwing the pan into the valve (Fig. 7-2). Take care not
to damage the attached pilot assembly when rotating the
burner pan. Be sure all connections are tight, however
do not overtighten to prevent damage to the valve.
Ensure the valve is properly installed as shown in Fig
7-3. The burner pan must rest flat on the fireplace floor.