Spec Sheet 1

14
LIGHTING INSTRUCTIONS (cont.)
Fig. 14-2 Proper pilot flame
MANUAL LIGHTING
CAUTION: DO NOT attempt to light the pilot by hand.
1. Locate the 3-position switch found on the front of the
heatshield (see Fig. 14-1). Press the switch up to the
ON position.
The remote receiver will emit an audible "beep"; then
the igniter will begin to spark. After the pilot lights and
is established, the valve will automatically open and
the burner will light.
Note: The ignition sequence will take approximately 5
seconds.
WARNING: If the pilot fails to light within 10 seconds,
turn OFF the system. Allow five (5) minutes
for any gas in the unit to dissipate, then
repeat step 2 above. IF YOU SMELL GAS,
SEE STEP B ABOVE.
If the pilot fails to light after several tries, turn the system
OFF and contact a qualified professional service technician.
Note: In manual mode, the remote transmitter will not
operate the burner system.
SHUTTING DOWN
For a remote shut down, press the OFF button on
the remote transmitter.
For a manual shutdown (or if your remote is
unavailable), press the switch found on the front of
the heatshield to the center OFF position.
PILOT APPEARANCE
Periodically check the pilot for proper flame pattern. The
pilot flame should encircle the generator tip, and is preset
at the factory (see Fig. 14-2).
If the pilot flame burns incorrectly; shut down completely
and contact a qualified professional service technician.
I
O
II
Fig. 14-1 Switch detail
ON
REMOTE
OFF
(switch is located on front of heatshield)