LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device that automatically lights the pilot. DO NOT attempt to
light the pilot by hand.
B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only the supplied switch or the control/remote system components to light the pilot. This valve will not
operate if the pilot is not lit and stable.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
under water. Attempted operation may result in fire or explosion resulting in property damage, personal
injury or loss of life.
OFF
ON
AUTO
ON
OFF
HI/LO
TIMER
Fig. 13-2 Remote transmitter detail
OFF/DOWN
key
ON/UP
key
HI/LO key
(Display
screen)
Timer
key
REMOTE LIGHTING
CAUTION: DO NOT attempt to light the pilot by hand.
Note: Step 1 may not be required if previously done during
an earlier lighting.
1. Locate the 3-position switch found on the front of the
heatshield (see Fig. 13-1). Press the switch down to
the REMOTE position.
2. Locate the remote transmitter and press the ON key
(see Fig. 13-2). The ignition sequence will begin.
The remote receiver will emit an audible "beep"; then
the igniter will begin to spark. After the pilot lights and
is established, the valve will automatically open and
the burner will light. Adjust to the desired setting(s) with
the remote transmitter. See the REMOTE OPERATING
INSTRUCTIONS section for details.
Note: The ignition sequence will take approximately 5
seconds.
WARNING: If the pilot fails to light within 10 seconds,
press the OFF button on the remote
transmitter or move the switch to the
center OFF position to turn OFF the
system. Allow five (5) minutes for any gas
in the unit to dissipate, then repeat step
2 above. IF YOU SMELL GAS, SEE STEP
B ABOVE.
If the pilot fails to light after several tries, turn all control/
remote system components to OFF and contact a qualified
professional service technician.
I
O
II
Fig. 13-1 Switch detail
ON
REMOTE
OFF
(switch is located on front of heatshield)