Spec Sheet 1
10
L-A2-376
Rev 1 - 1904120815
Fig. 10-1
Control module
Wire harness
connector
Check connections
"I" wire
"S" wire
A
TO CHECK THE WIRING ASSEMBLY
1. Check that the wiring harness is fitted tightly into the
connector on the green ignitor pack attached to the
valve (Fig. 10-1, A).
2. Check that the female connectors on the two black
wires from the pilot assembly (wires marked "I" and
"S") are inserted fully into the male connectors on the
ignitor pack (Fig. 10-1, B).
3. Check the connections of the wires to the valve (see
Fig. 10-2 C ).
The diagram below (Fig. 10-3 and Fig. 10-4) shows the
wiring layout for the complete unit.
B
INSTALLATION (Cont.)
CHECKING THE CONTROL MODULE
The valve system comes completely assembled with the wiring harness already connected. However,
we recommend that you follow the steps below to ensure it has not become detached during shipping before
connecting to the power supply.
Ground wires
Fig. 10-3
EPK-2V WIRING DIAGRAM EPK-3V WIRING DIAGRAM
Control
valve
Ignition
module
pack
Pilot/Igniter
assembly
Switch
Wire
harness
Control
valve
Ignition
module
pack
Pilot/Igniter
assembly
Switch
Wire
harness
Shut off
valve
AC adapter
AC adapter
Fig. 10-4
Wire harness
Ground wires
Wire harness
Check connections
Fig. 10-2
3V model
2V model
C