Installation guide

-8-
Seismic Restraint
If seismic restraint is required then use the strap provided, Slide
the strap through the bottom back rail of the fire box and secure
to the cavity base.
Masonry Cavity
Cavity Design
NOTE: Remember that both gas and electricity are required within the cavity
(Refer to Notes on
Installation, page 5)
Notes:
These instructions are for either new masonry/non combustible cavities or existing masonry fire places.
A flexi flue and adaptor is available for installations where access is restricted.
If the cavity can be completed after the firebox and flue are installed then the adaptor might not be
required.
The flue adaptor can also be used with rigid flue where space allows.
The flue should be self supporting before the firebox is installed.
This fire is not designed for installation without a dedicated flue liner
This fire consists of a firebox and removable
insulating panels. For masonry installations
only, these panels can be removed if cavity
space is restricted. Remove as few or as many
panels as required. The more panels retained,
the more efficient the fire will be.
Take care not to damage the power cord when
removing the back panel!