Installation guide
9
© 2010 Directed Electronics. All rights reserved.
Feature Menu
Default settings are in bold type.
Feature
#
Feature Opt. 1 Opt. 2 Opt. 3-5+
1 Engine check-
ing
Virtual tach
voltage (3) Off, (4)
Tachometer
2 Remote Start
Engine Runtime
12 min
24 min 60 min
3 Park light
output
Pulsed
Constant
4 Cranking time
0.6 sec
.
0.8 sec. (3) 1.0 sec.
(4) 1.2 sec.
(5+) 1.4,
1.6, 1.8,
2.0, 4.0 sec.
5 Remote Start
activation pulse
count
1 pulse
2 pulses 3 pulses
6 2nd Ignition /
Acc Output
Ignition
Accessory
7 Accessory
output
Off during
wait-to-start
On during
wait-to-start
8 Status behavior
Normal
Latch rear
defogger
Pulse rear
defogger
9 Diesel Wait-To-
Start timer
Off
Timed 15 sec Timed
(3) 30 sec.
(4) 45 sec.
10 Virtual Tach
fine tune
0 (as learned)
100 ms to 1 sec. (in 100 ms
increments)
11 Factory Alarm
Disarm Pulses
Single
Double