CONFIRM THAT THE CUSTOMER-SUPPLIED FRAME IS MADE TO ACCOMMODATE THE
DIMENSIONS AS ILLUSTRATED ABOVE.
1. Unpack AA100 unit from carton and inspect for shipping damage. Contact Ready Access as soon as possible if
damage has occurred. (800) 621-5045
2. A rough opening of 22-1/4" (565 mm) W x 12" (305 mm) H must be constructed before installation of AA100 unit.
3. Remove the (4) #2 phillips drive screws from the AA100 unit inside cover. This will allow access into unit once in
position of rough opening.
4. Position AA100 unit into rough opening, flush with inside of window unit. (Approx. 5" max. in from the outside of
window unit.)
5. Secure into position using the (4) 5/16" self-tapping screws provided through the mounting holes in the side panels of
unit. If mounting into masonry, use 1/4" (6 mm) masonry anchors (Not Provided).
6. Flash and seal unit on the outside to prevent water leaks and trim inside for cosmetics.
7. Close unit when completing installation using the (4) #2 phillips drive screws.
PLEASE COMMUNICATE WITH ELECTRICIAN ON UNIT AND INSTALLATION INSTRUCTIONS.
REINSTALLED SMALLER
TRANSOM GLASS
Tools Needed for Installation
¼” Nut Driver
” Drill
5/16” Socket Adaptor to Drill Caulk and Caulk Gun
4 5/16 “ x1” Self Tapping Screws