Specifications
29 
SERVICE 
Troubleshooting Guide 
Issue  Probable Cause  Resolution 
•  No power to the controller unit 
Ø  Main Circuit breaker is 
defective or not “ON” 
Ø  The fuse on the power 
supply is blown 
Ø  Main power rocker switch is 
defective 
Ø  AC wiring is defective 
Ø  Reset or replace the main circuit 
breaker in the load center 
Ø  Replace the fuse on the power 
supply 
Ø  Test rocker switch with an 
ohmmeter. Replace if necessary 
Ø  Check AC wiring for opens. Replace 
if necessary 
•  Red Lamp/s not illuminating  •  Replace the PCB assembly cover 
•  The 4 pin power connector to 
the main PCB assembly is not 
secure 
•  Secure the connector/s to the power 
supply 
Power switch in the 
“ON” position but the 
light is not illuminated. 
•  The connector/s to the rocker 
switch are not secure 
•  Secure the connector/s to the rocker 
switch 
•  Defective electric eye assembly 
Ø  Pressing the “BEAM TEST” 
button on the controller unit 
can test this. The door 
should open, pause and 
close. If the door operate 
normally, check other 
causes listed below 
•  Replace the electric eye assembly 
•  Loose electric eye cable from 
the PCB 
•  Secure the cable connector (3 or 4 pin) 
•  Loose or broken wire/s in the 
electric eye cable 
•  Check that the electric eye cables are 
secure and not broken 
•  Defective lamp  •  Replace the PCB assembly cover 
“BEAM BREAK” lamp is 
“OFF” and does not 
illuminate when the 
electric eye is broken. 
•  Defective PCB assembly  •  Replace the PCB assembly 
•  Loose or broken wires to the 
limit switches or the PCB 
assembly 
•  Secure or replace the cable assembly 
The door will not “AUTO 
REVERSE” for an 
obstruction when 
closing and the motor 
continue to run. 
The “CURRENT 
DETECT” lamp will not 
illuminate. 
•  Defective controller unit  •  Replace the controller unit 