Specifications

25
Calibration:
The only calibration available on the new style DC-3 PC board is setting the close delay timer using the
dip switch package mounted near the ribbon cable connector.
The CLOSE DELAY TIMER is default set at 3 seconds
The DC-2 PCB has two potentiometers
The Window Select Dial is used to set the type of door
configuration for the model of window.
The Current Dial is used to increase or decrease the
power to the motor. This is adjusted to insure proper
operation.
Follow the Chart Below for Changing
The Close Delay Time Settings
Dip Switch Settings
Switch Position Time in
Seconds
1 2 3 4 5
1
ON
OFF OFF OFF OFF
2 OFF
ON
OFF OFF OFF
3 OFF OFF
ON
OFF OFF
4 OFF OFF OFF
ON
OFF
5 OFF OFF OFF OFF
ON
12
ON ON
OFF OFF OFF
13
ON
OFF
ON
OFF OFF
14
ON
OFF OFF
ON
OFF
15
ON
OFF OFF OFF
ON
23 OFF
ON ON
OFF OFF
24 OFF
ON
OFF
ON
OFF
25 OFF
ON
OFF OFF
ON
34 OFF OFF
ON ON
OFF
35 OFF OFF
ON
OFF
ON
45 OFF OFF OFF
ON ON