NDA-24213 CHAPTER 3
Page 19
Issue 3.0
Connection Drawings
Installing the PN-CC00 and the PN-AP01
CHAPTER 3 Connection Drawings
Figure 3-1 PN-CC00 Connection through 10 Base T Transceiver
1. Installing the PN-CC00 and the PN-AP01
STEP 1: Mount the PN-CC00 in any slots LT10 (AP0) - LT15 (AP05). The PN-CC00 requires two LT (AP)
slots.
STEP 2: Mount the PN-AP01 in any slot LT10 (AP0) - LT15 (AP05).
STEP 3: Set the PN-AP01 SENSE 0 switch to the slot number that is programmed in CM05 (see Chapter 4,
Heading 1, “AP01 Initialization”).
STEP 4: Install the 48-TW-0.3 connecting cable from the DCB A connector of the PN-CC00 card to the
bottom connector of the PN-AP01 card.
STEP 5: Install the Ethernet cable from the AB Ether connector of the PN-CC00 card to the 10 Base T
transceiver.
STEP 6: Install the Ethernet cable from the transceiver to the network driver of the Server.
Note:
One end of this cable must be reversed.
1.1 Crossover Reverse Pin-out
Figure 3-2 Crossover Reverse Pin-out
NEAX2000 IVS
PN-CC00
PN-AP01
10 Base T
Transceiver
CallCenterWorX Server
Note: One end of this cable
must be reversed.
48-TW-0.3 Cable
Ethernet Cable
Cable
Ethernet
Interface
Cards
Crossover/Reverse
T
TxD+ 1
1 TxD+
TxD- 2
2 TxD-
RxD+ 3
3 RxD+
RxD- 6
6 RxD-
NOTE:
1. Pins 4,5,7,and 8 not used.
2. Use for going from 10
Base T transceiver to PC.