User manual

Smart_DP RM 9600 User Manual
Seite 11
F.2 Configuration via the RS-232 interface
The Profibus-DP/RS-232 module can be configured through a tool via the RS-232 interface.
However, the settings given by the GSD file, (they are especially adapted to the radio
modem) should be used. That ensures the right functionality.
F.2.1 Installation of the tool
Start the program 'setup.exe' from the corresponding directory of the delivered CD
('...\ConfigSer') for the software 'Smart_DP Serial Configuration-Tool' and follow the instruc-
tions on the monitor.
After successful installation the program 'Smart_DP Serial Configuration' can be started from
the task ledge under the program group 'b-plus'.
F.2.2 Usage of the 'Smart_DP Serial Configuration-Tool'
In order to get a connection via the 'Smart_DP Serial Configuration-Tool' to the Profibus-
DP/RS-232 interface the following steps have to be carried out:
1. Connect the Smart_DP module through a zero modem cable (crossed data lines) to a free
serial port of the PC.
2. Start the application 'Smart_DP Serial Configuration' from the task ledge under the pro-
gram group 'b-plus'.
3. Choose the COM port of the connected Smart_DP module.
4. Power up the Smart_DP module when the starting window of the application is shown on
the screen.
5. After a short moment the buttons ('Read', 'Write', 'Reset') aren’t shadowed any more (they
are active now). Further on, the fields 'Firmware version' and 'Serial No' now contain the
corresponding entries. The connection to the Smart_DP is now established.
If setting up a connection to the module is not possible, the program will finish automati-
cally after 10 seconds.