User's Manual
ControlPanelForLowOccupancy(XL)Fixtures
AreaX1DialSwitch:
Thisdialissetto
indicatetheflooror
areaaparticular
fixtureisbeing
installedon.Ifthe
fixtureisbeing
installedonthe4
th
floor,thisdialwould
besetto“4”.Ifthe
fixtureisbeing
installedonthe23
rd
floorthisdialwouldbe
setto“3”,etc.
ZoneDialSwitch:Some
facilitieshavemorethanone
buildingorareastoilluminate.
Thisswitchhelpstokeep
fixturesinonebuildingorarea
fromtalkingtofixturesin
adjoiningbuildingsorareas.If
you’reonlyilluminatingone
area,usea
smallstraightslot
screwdriverandsetthedialto
“1”.Formultiplebuildingsor
areassetthedialaccordingly.
Timer:Oncethefixtureseesmotionwithinanareait
willimmediatelyilluminatetofullintensity.Asmall
screwdriverisusedtoadjustthe“Timer”.ThisTimer
adjuststhelengthoftime
thatthefixtureremainson
atfullpowerpriortoreturningtothe“DIM”setting.
TurningtheTimerallthewaytotheleft(counter
clockwise)willkeepthefixtureonathighpowerfor
only10‐seconds.TurningtheTimerallthewaytothe
right(clockwise)willkeep
thelightsonatfullpower
for5‐minutesafterthesensorseesitslastmotion.
Thetimecanalsobesetanywherebetween5‐
secondsand10‐minutesbypositioningtheTimer
accordingly.
StatusIndicatorLED:Thisisa
bi‐coloredLED(RedorGreen).
ThisLEDprovidestheoperator
withthecurrentsystemstatus.
Seethetableonthenextpage
foradetaileddescriptionof
thevariousindications.
Self‐Diagnostic:Periodicallyit’sagood
ideafortheoperatorstopushtheSelf‐
Diagnosticbuttontorunthebuilt‐in
testingprogram.ResultsoftheSelf‐
Diagnostictestarereported
onthe
“DIAG”LEDIndicator.Seethetableon
thenextpageforadetaileddescription
oftheindications.
Self‐DiagnosticStatusLED:Thisis
abi‐coloredLEDs(RedorGreen).
ThisLEDprovidetheoperator
withtheself‐diagnosticteststatus
andresults.Seethetableonthe
next
pageforadetailed
descriptionoftheindications.
7
AreaX10DialSwitch:This
dialissettoindicatethe
floororareaaparticular
fixtureisbeinginstalledon.
Ifthefixturesarebeing
installedonfloors1‐ 9,this
dialwouldbesetto“0”.If
thefixtureisbeinginstalled
onfloors10– 19,thisdial
would
besetto“1”.Ifitis
beinginstalledonfloors20
– 29,thisdialwouldbeset
to“2”,etc.
EXAMPLE#1:Ifafixtureisbeinginstalledinthesecondstairwellofabuildingonthe17
th
floor,thedialindicators
wouldbesetlikethis:217.
EXAMPLE#2:Ifafixtureisbeinginstalledinabuildingwithonlyonestairwellonthelandingbetweenfloors5and
6,thedialindicatorswouldbesetlikethis:105.
NOTE:Landingsbetweenfloorsshouldhave
thesamedialsettingsasthefloorjustbelowit…i.e.Afixtureinstalled
onalandingbetweenfloors2and3shouldhavethesamedialsettingsasthefixtureonfloor2.
XeleumLighting,LLC.333NorthBedfordRd.MountKisco,NY10549*Phone954‐617‐8170*Fax954‐571‐9777*www.xeleum.com
ArtemisSeriesofLowOccupancyLED
CeilingMountedFixtures(IncludingStairwells)
Installation&OperationGuide
ZONEX10AREAX1
DIM
HILOWOFF
POWER
HILOW
“DIM”Settingcontrols
thelightlevelwhenthe
stairwellisun‐occupied.
“POWER”Setting
controlsthelight
levelwhenthe
stairwellisoccupied.
XL
ZONEX10AREAX1
TEST