User manual

VLA-120 C / VLA-240 C VARIO-LINE
4
V O R D E R S E I T E
1. MIC / LINE LEVEL
- P.T.T 1 VOLUME / EQ VOLUME
P.T.T 1 volume control / EQ volume control let you adjust input
1level and P.T.T remote (VLM-100) level. BASS and TREBLE CON-
TROLS make you adjusted equalizer so as to suit for surrounding
usually, first, position adjusted should be set at "0" of LED indica-
tor with two 0`clock of MASTER volume. Second, you can increase
input volume to the position "0" of LED indicator.
- IMPORTANT NOTE : 1. In case the priority function is activa-
ted, if you supply signal to MIC/LINE 1, then, all signals including
LINE 4, 5, PAGING RINGER and module signals will be closed ,set
Jumper MS 2 on the FRONT PCB to "SLAVE".
2. Also,P.T.T remote signal makes priority same as priority func-
tion of MIC/LINE 1 (except signal of VLM-205). But if you select
switch of remote controller to "SLAVE", signal of remote control
will be cut-off.
1. MIC / LINE LEVEL
- P.T.T 1 Regler / EQ Regler
P.T.T 1 Regler für Lautstärke und EQ Regler für Tiefen sowie Hö-
heneinstellung des Eingang 1 und des P.T.T REMOTE Eingang, (
VLM-100 ) immmer in Verbindung mit "MASTER" Regler.
Die LED Anzeige sollte nicht über "0" ansteigen.
- WICHTIG :
Falls die Prioritätsfunktion aktiviert ist, können nur Signale die auf
dem Eingang 1bzw. P.T.T REMOTE (7-pol. DIN-Buchse) anliegen,
empfangen werden.
Die Eingänge 4, 5, NIGHT RINGER, PAGING IN und alle Modulsi-
gnale (außer DM-10) sind gesperrt, vorausgesetzt der Jumper
MS 2 (hinter Abdeckpaneel des Modulleerfeldes) steht auf
"SLAVE".
Diese Prioritätsfunktion besteht nicht , wenn der Schalter der
Sprechstelle (VLM-100) auf "SLAVE" (OUT) steht.
AMP SECTION
- AUTOMATIC VARIABLE SPEED FAN
- OVER CURRENT PROTECTION
- OVER HEATING PROTECTION
- LOAD SHORT CIRCUIT PROTECTION
- BUILT IN L.P.F. ( LOW PASS FILTER ) CIRCUIT
- OUTPUT LED INDICATOR
- 5 ZONE SPEAKER OUTPUT OR ALL CALL
- SPEAKER ATTENUATOR PER CHANNEL BY 6 STEP
PRE AMP AND OTHER
- INPUT GAIN VOLUME CONTROL PER MICROPHONE
- SELECTIVE PHANTOM POWER PER MICROPHONE
- DIN CONNECTER FOR P.T.T. MICROPHONE INPUT
- RCA JACK FOR LINE 4, 5 INPUT
- RCA JACK FOR RECORDING OUTPUT
- CONNECT FOR PRE-OUT/EXTERNAL AMP IN
- EQUALIZER PER INPUT CHANNEL
- TELEPHONE PAGING AND NIGHT RINGER
- 2- or 4-TONE CHIME (switchable with Jumper MS 1)
- SIREN
- OPTIONAL MODULE CONNECTION
(CR-10, TP-10, CP-10, DM-10, CDP-10, CDR-10 )
- REMOTE CONTROL FOR POWER ON / OFF
- SOFT START FOR BATTERY POWER SUPPLY DELAY
- REMOTE CONTROL SYSTEM BY RJ45 CONNECTOR
1. DIGITAL MESSAGE
2. CHIME
3. CONNECTION WITH 3 MODULES SIMULTANEOUSLY
- AUTO ALERT ANNOUNCEMENT AND AUTO POWER"ON"
CONNECTING TO DIGITAL MESSAGE ( DM-10A )
(MESSAGE FIRST PRIORITY CONNECTING WITH FIRE ALARM)
- MIC 1, 2, 3 PRIORITY SELECTOR SWITCH
Hauptmerkmale
- Automatische Anpassung der Lüftergeschwindigkeit
- Kurzsschlußschutz
- Überhitzschutz
- Leerlaufschutz
- Low Pass Filter
- Ausgang LED- Pegel Anzeige
- 5 Lautsprecherkreise und Summe
- Lautstärkereglung pro Kreis in 6 Stufen
Weitere Funktionen
- MIC-Eingänge mit Gain-Regler ( Combo-Buchsen )
- Wahlweise Phantom-Power
- 7-pol DIN-Buchse für P.T.T. Microphon ( VLM-100 )
- Chinch-Buchsen für LINE-Eingänge 4,5
- Chinch-Buchse für REC Output,unsymm., 0 db
- PRE OUT und AMP IN Klinkenbuchsen, 6,3 mm
- Für jeden Eingang Bass und Höhenregelung
- TEL-OUT für PAGING IN und NIGHT RINGER
- Elektronischer 2- oder 4-Klanggong (umstellbar mit Jumper
MS 1 unter Lerrblende)
- Sirene umschaltbar auf Alarmton
- Leerfeld für Tonträgermodule
(CR-10, TP-10, CP-10, DM-10, CDP-10, CDR-10 )
- Fernbedienung für POWER "ON/OFF"
- SOFT START
- Fernsteuerung über digitale Schnittstelle RJ 45
1. Digitales Textmodul (Option)
2. Sirene
3. Verbindung von mehreren VLM-105/205 gleichzeitig
- AUTO POWER "ON" und automatische Alarmdurchsage
über digitales Textmodul DM-10A
(Priorität von Durchsage und Feueralarm möglich)
- Schalter für Priorität von MIC-1, 2 und 3
VLA-240
VARIO-LINE P.A. AMPLIFIER