Owner's Manual
NATURAL GAS INSTALLATION –
The installation must conform with local codes or, in the absence of local codes, with either
The national Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas
Installation Code or CAN/CGA-B149.2, Propane Installation Code.
1. This gas appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at the test pressures in excess of 1/2
psi (3.5 kPa).
2. This appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the as supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
If the gas Pro Burner is factory built for natural gas, the regulator needs to be set for 4” water
column. The regulator is convertible Later to 10” water column for system LP application. Do not
use with a 20-lb LP cylinder.
Make sure that the regulator is set for natural gas. To check, remove the top cap. You will find
the conversion plastic pin attached to the cap to the underside of the cap. If the disc (1/2 in.
diameter) of the pin is close to the cap, then the regulator is set for natural gas. If the disc is at
the tip of the pin, away from the brass cap, the regulator is set for system LP application. To
convert to natural gas, remove the plastic conversion pin and invert and replace it back in a
manner such that the disc is close to the brass cap. For both natural and LP, the maximum inlet
pressure is 14” water column.
Do not use any replacement regulator other than that specified by RCS. Use only pipe
sealants that are approved for use with natural and LP gases. An installer-supplied gas Shutoff
valve must be installed in an accessible location.
LEAK TEST
CAUTION BEFORE TESTING
Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure.
NEVER USE THE PRO BURNER WITHOUT FIRST LEAK TESTING THE GAS
CONNECTIONS.
WARNING: DO NOT USE OPEN FLAME TO CHECK FOR LEAKS.
USE OF AN OPEN FLAME COULD RESULT IN A FIRE, EXPLOSION AND BODILY HARM.
DO NOT SMOKE WHILE PERFORMING THE LEAK TEST!
IF AT ANYTIME YOU SMELL GAS – SWITCH OFF ALL OF YOUR EQUIPMENT AND CALL A
PROFESSIONAL TO DETECT THE GAS LEAK. ALWAYS INFORM ALL MEMBERS OF YOUR
FAMILY ABOUT THIS IMPORTANT FACT – SMELL GAS = DO NOT USE THE EQUIPMENT.