Specifications
36
3636
36
17. Troubleshooting
The incubator data can different from computer data when you started
incubation not from computer but from incubator.
The computer data is different
from incubator data.
9
Even if the connection of USB cable is removed or the program is
terminated on incubation, the incubator keep the change of
temperature and humidity and transmit to PC when it connected.
During transmitting, the graph can not appear.
Real-time temperature and
humidity graphs are not
indicated.
Short of water or humidification pad does not have enough absorbing
power because of impurity on the water. In this case, boil the
humidification pad on the water diluted with 10% of vinegar.
Incubator humidity cannot meet
the setting humidity value, and
real-time graph draws irregularly.
This case can occur when you terminate the program or remove USB
cable before all temperature or humidity data transferred to the
incubator. When you want to terminate the program or remove USB
cable, be sure to check this sign is disappeared.
The temperature and humidity is
not applied normally.
When you use the incubator first time, the computer does not connect
with computer at once, and find computer connecting port
automatically. It takes about 1~2 min. After it finds connecting port
once, it directly recognize the port later.
Without power supply, the connecting sign does not show.
You connected the incubator
with computer, but the
connecting mark is not appear.
You did not input exact egg data or the range of data goes off the rails.Weight & Density loss graph is
not indicated well.
You added new( non registered) species of birds on program logo
window. It is normal, and there is no problem. You also can upgrade
firmware version later.
There is no D-Day display and
Bird icon on LCD.
It can be various from connecting conditions between incubator and
PC. But if it repeats continue, try to the solution No.1
Incubation starting alarm sounds
more than 2 times.
Take off incubator power cord and cut power supply. Put the power
cord again after 1~2min.
Incubator doesn’t operate
normally on the program.
SolutionsCircumstance
Incubation condition data which is input on the computer is regular conditions.
The conditions can be different from the species of birds or state of birds.
1
2
3
4
5
6
7
8
9