Specification

According to Regulation (EC) No.1907/2006 FUHAI SHUNJI
SAFETY DATA SHEET
Date: Mar.2014
page 3 of 6
Spontaneous/explosive re-ignition may occur. Extinguish any
other fire.
Special protective
equipment for fire fighters
In confined space use self-contained breathing apparatus.
6
Accidental release measures
Personal
precautions
Wear self-contained breathing apparatus when entering area unless
atmosphere is proved to be safe.
Evacuate area.
Ensure adequate air ventilation.
Eliminate ignition sources.
Environmental
precautions
Try to stop release.
Prevent from entering sewers, basements and work-pits or any place
where its accumulation can be dangerous.
Clean up measures
Ventilate area.
7
Handling and storage
Handling
Take precautionary measures against static discharge.
Suck back of water into the container must be prevented.
Purge air from systems before introducing gas.
Do not allow back-feed into the container.
Use properly specified equipment which is suitable for this product, its
supply pressure and temperature. Contact your gas supplier if in doubt.
Keep away from ignition sources (including static discharges).
Refer to suppliers container handling instructions.
Storage
Segregate from oxidant gases and other oxidants in store.
Keep container below 50 in a well ventilated place.
8
Exposure controls/ personal protection
Personal protection
Wear suitable protective clothing, gloves and eye/face protection.
Wear thermal insulating gloves when handling liquefied gases. In cases of
insufficient ventilation, where exposure to high concentrations of vapour is
possible, suitable respiratory protective equipment with positive air supply
should be used.
Do not smoke while handling product.
Eye protection
Gloves
Occupational exposure limits
Iso-butane: TLV-TWA [ppm]: 800