Installation guide
Installation/Mounting the Dish 55
11. Insert expansion anchors in each hole.
12. Use four 1/4" x 20 x 1-1/2" machine screws and 1/4" washers to attach the
mounting foot to the wall. Tighten all four screws.
13. Vertically Level the dish with a bubble level or plumb line.
To do this, place the level, or plumb line, on the mast at an parallel angle to the
wall. If you have not loosened the two bolts securing the azimuth adjustment
on the mounting foot, do it now. If you are using a bubble level, move the mast
vertically to center the bubble in the window of the level. If you are using a
plumb line, hold the string of the plumb line over the top of the mast so it hangs
at a perpendicular angle to the mounting surface. Move the mast vertically until
the plumb line hangs parallel to the side of the mast. Tighten the two mounting
both securing the mast to the mounting foot. For a more detailed description of
this procedure, see the Leveling the Dish section of this manual.
14. Check tightness of all bolts and proceed to the Assembling the Dish Compo-
nents section.