Operating instructions
14
Model Bottom
1. Bind button
2. Hook-and-loop tape for
battery fastening
3. Connection socket for ight
battery
4. Battery holder
9. SAFETY INSTALLATION
The “RC EYE One S” has a range of safety devices in the transmitter and model which protect
the model from damage and/or should reduce possible damage to a minimum. The protection
mechanisms are identied by LED indicators (model) or an acoustic warning signal (transmitter).
Transmitter
> The charge condition of the inserted batteries is inspected every time the transmitter is switched on. If
the charge condition is too low, the transmitter switches off immediately again. The transmitter signals
this by three subsequent warning sounds.
> The charge condition is continually inspected while the transmitter is in operation. If the charge condition
drops below a certain value, the transmitter also signals this with a triple warning sound. In this case,
stop ying at once and replace the batteries of the transmitter.
> The transmitter also has a deactivation automatic integrated. If no control element is operated for more
than ve minutes, the transmitter switches off automatically.
> TX with xed timer function:
Alarm I : 4 min 1 x beep [3 sec pause], 1 x beep [3 sec pause], 1 x beep [3 sec pause], 1 x beep
Alarm II : 5 min 2 x beep [3 sec pause], 2 x beep [3 sec pause], 2 x beep [3 sec pause], 2 x beep
Alarm III : 6 min 3 x beep [3 sec pause], 3 x beep [3 sec pause], 3 x beep [3 sec pause], 3 x beep
Alarm IV : 7 min 4 x beep [3 sec pause], 4 x beep [3 sec pause], 4 x beep [3 sec pause], 4 x beep