Instructions

32 | Calibration
27.5.3.3 6-channel transmitters:
When using a 6-channel transmitter, trigger R.T.H. by turning the transmitter off.
Additionally,setchannel5to+30%inthe‘failsafe’status.Refertotheuserinstructions
ofyourtransmitterandreceiver.
27.5.4 Futaba
®
transmitters without 3-way-toggle-switch
Incaseyoudonothaveafree3-waytoggleswitchavailableonyourtransmitter,youmay
assigna2-way-toggle-switchinsteadandshiftyourchannelEND POINT after performing
thelearningprocedureonyourtransmitter.See [ Fig. 11 ].
> BydefaulttheEND POINTforchannel5(ightmodeswitch)issetto“135100”.This
defaultsettingletsthe2-way-toggle-switchfunctionasthebankselectionswitch(AP
mode, Sport mode).
> Totogglebetweenthesetwomodesinstead,simplyshifttheEND POINTto“0100”
for the affected switch. See [ Fig. 11 ].
> Youmayusethesameapproachforchannel6(AP,SportandCustommode).
LINKAGE MENU 1/2
SERVO : SUB-TRIM
MODEL SEL. : REVERSE
MODEL TYPE : FAIL SAFE
FREQUENCY : END POINT
FUNCTION : THR CUT
END POINT 2/2
LIMIT
AUX1 0 100 6 100 135
AUX2 135 100 7 100 135
AUX3 135 100 8 100 135
AUX4 135 100 100 135
Fig. 11
27.6 Calibrating the gyro
You MUST perform this step with precision or the »NovaX
350 won’t fly properly.
1. Study [ Fig. 12 ].
2. Switchtothegyrocalibrationprocedure.Referto‘27.3 Switching between learning/
calibration’onpage28.
3. Start the procedure.
4.
Replace the canopy
.
5. Placethe»NovaX350onahorizontalandlevelsurface
[1]
and wait for a single beep.
6. Rotatethe»NovaX350by180°aboutitsverticalaxis
[2] [3]
.
7. 2beepsconrmthesuccessfulcompletionofthegyrocalibrationprocedure.
8. Removethecanopy.
9. Complete the procedure.
27.7 Calibrating the compass
You MUST perform this step with precision or the
»NovaX 350 won’t fly properly. Perform the compass
calibration in an open area, away from metal objects, high-
voltage powerlines, radio towers/masts and any portable
or stationary devices sending and receiving radio signals in
order to eliminate magnetic interference.
1. Study [ Fig. 13 ].
2. Switch to the compass calibration procedure. Refer to ‘27.3 Switching between
learning/calibration’onpage28.
3. Start the procedure.
4. Replacethecanopy.