3.4.2.2 Total discharge
> Since discharging below 3.0 V per cell would lead to permanent damage of the
rechargeable battery pack, this total discharging is to be prevented as far as possible.
> For safety reasons, programmable cruise controls/ight control systems should be set
in such a way that the undervoltage detection responds already at a voltage of 3.0 V
per cell (Example: 3 cells = 9.0 V cut-off voltage). Alternatively, the optical undervoltage
displays are also recommended.
3.4.2.3 Correct dimensioning
> As the current drawn rises, the battery pack warms and the usable capacity is lowered.
The ideal operating temperature during discharge is between +20 and +40 °C and must
not exceed +60 °C even under extreme load.
> The maximum short-time current that can be loaded to the battery pack is stated in
the technical data sheets or can be read directly from the battery pack. The value “C”
always refers to the capacity value of the respective battery pack.
Example:
A battery pack with a capacity of 2100 mAh and ”20 C” can
be loaded with 2100 mA x 20 = 42 A maximum.
> However, the maximum permissible continuous current is clearly lower. If there are no
precise manufacturer’s specications, the battery pack should not be loaded with more
than approx. 50 % of the maximum permissible surge current over a long term.
3.5 Miscellaneous
> Consult an expert when in doubt about operation, safety or connection of the device.
> Maintenance, modications and repairs are to be performed exclusively by an expert
or at a qualied shop.
4. PRODUCT SUPPORT
Visit http://www.rclogger.com/index.php/contact-us or call +852 2559 2662 for product
support. Additionally visit our support forum at http://rclogger.com/forum.
5. LEGAL NOTES
This information is published by CEI Conrad Electronic International (HK) Limited, 18th
Floor, Tower 2, Nina Tower, No. 8 Yeung Uk Road, Tsuen Wan, New Territories, Hong Kong.
All rights including translation reserved. Reproduction by any method, e.g. photocopy,
microlming, or the capture in electronic data processing systems require the prior written
approval by the editor. Reprinting, also in part, is prohibited. The information reect
the current technical specications at time of print. We reserve the right to change the
technical or physical specications.
© 2013 by CEI Conrad Electronic International (HK) Limited
V1-1213-02-JH(1)