User manual
These operating instructions are published by CEI Conrad Electronic International (HK) Limited, 18th Floor, Tower 2,
Nina Tower, No. 8 Yeung Uk Road, Tsuen Wan, New Territories, Hong Kong. All rights including translation reserved.
Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic data processing systems
require the prior written approval by the editor. Reprinting, also in part, is prohibited. The operating instructions reect
the current technical specications at time of print.
© 2017 by CEI Conrad Electronic International (HK) Limited 10010RC_v4_0217_02_EN_(3)
FIRMWARE UPGRADE
PC
AdaptermicroUSB cable
Upgrade the gimbal rmware as follows:
1. Download the rmware upgrade tool from www.rclogger.com. Follow the instructions given
in the tool.
2. Download the latest rmware from www.rclogger.com.
3. Connect the gimbal to your computer as shown in the above image. Make sure to use the
supplied USB adapter.
4. Refer to the instructions given in the rmware upgrade tool to upgrade the gimbal to the
latest rmware version.
DISPOSAL
In order to preserve, protect and improve the quality of environment, protect human
health and utilise natural resources prudently and rationally, the user should return
unserviceable product to relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately
and not as municipal waste.
Consequently you comply with your legal obligations and contribute to environmental protection!
FCC COMPLIANCE STATEMENT
FCC ID: SXYRCL-TX58
Statement according to FCC part 15.19:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
> This device may not cause harmful interference, and
> This device must accept any interference received, including interference that may cause
undesired operation.
Statement according to FCC part 15.21:
Modications not expressly approved by this company could void the user’s authority to operate
the equipment.
PRODUCT SUPPORT
Visit http://www.rclogger.com/support or call +852 2559 2662 for product support. Additionally
visit our Online Ticket System at http://support.rclogger.com for any RC Logger inquiry.
TECHNICAL DATA
Update the NovaX 350 firmware to at least version FW v1.5
in order for you to be able to use the manual and automated
calibration features of the gimbal.
Item Min. Standard Max. Remarks
Operating voltage 7 V 8.4 V 17 V
Static Attitude Tracking
Accuracy
0.01 0.02 0.05 Gimbal in static mode
Motion Attitude Tracking
Accuracy
0.1 0.2 0.5 Motor overload <2G
Overload Current
Protection
800 mA
Pitch Angle -90° (Down) 0° (Horiz.) +45° (Up)
Roll Angle -45° 0° (Horiz.) +45°
Heading Angle -120° +135°
Pitch Following Rate 2°/sec 25°/sec
Heading Following Rate 3°/sec 75°/sec
Frequency 5.733 – 5.866 GHz
Transmission power <25 mW
Antenna 3 dB
Number of RF channels 8
Operating distance 300 m (open eld)
Weight 206 g (without camera)