Installation Manual Part 6

EXHIBrrc
C-2000 DIGITAL AIRBORNE TELEPHONE SYSTEM
FCC ID: CDG-ARTU
MAGNASTAR
MMT SOFTWARE LOADING
8.0
This section covers loading of MMT software onto the MMT host computer.
The host computer must be a 386 or faster IBM compatible computer with 4 Megabytes of RAM.
a 3.5" high density floppy drive. and at least 1 Megabyte of memory available for use on the hard
drive. For the MMT software to run property it is important that the C: partition is no larger than
1.5 Gigabytes and be designated FAT or FAT 16. The MMT software must be executed from
DOS and cannot be run from Windows or a Windows DOS shell. A RS-232C serial port and
serial cable (PIN 422632-801) are necessary for connection to the MagnaStar C-2000 system.
Execution of the MagnaStar Maintenance Terminal (MMT) software can only occur after it is
loaded in the host computer memory. This loading process will only be required to be performed
the first time the MMT software is to be used or if an updated version is required. The host
computer when loaded with the MagnaStar Maintenance Terminal software will be referred to as
the MMT. Loading of the MMT software will automatically start the execution of the MMT after
the completion of the software download to the computer's memory. The following steps are to
be used if the MMT software has not been loaded into the host computers memory or if an
updated version is to be loaded:
Power up the computer and wait for the computer to complete the boot process. After
the computer has completed the boot sequence, insert the 3.5- MagnaStar Maintenance
Terminal (MMT) software disk in the appropriate drive (A or B) of the computer.
If you placed the diskette in the A drive use the following commands: From the root
directory type "A:\MMT COPY" . then press "ENTER" to execute this command.
C:>A:\MMT COpy IENTERI
If you placed the diskette in the B drive use the following commands: From the root
directory type "B:\MMT COpy B" , then press "ENTER" to execute this command.
C:>B:\MMT COpy B I ENTERI
The "MMT COPY" command will automatically load all the software files and create the
necessary directories required to operate the MMT software. This command will also
start the execution of the MMT software.
RevB
8-