User's Manual

P25net Channel Controller Operations Manual
3-16
3.10.3.4 Turn off the generator and change the level to -118dBm. Turn on the
generator and verify RSSI goes to 30000 or above on the oscilloscope
(Figure 3-17).
Figure 3-17 RSSI High Level
3.10.3.5 Turn off the generator; RSSI settings will be saved when exiting PCCT.
3.10.4 Rx Calibration
3.10.4.1 From the Configure>Rx and Tx Manual screen set the following to default
values:
Rx Gain to 15
Rx Offset to 30