User's Manual

P25net Channel Controller Operations Manual
3-14
3.10.2 Initial Steps
3.10.2.1 Configure the test set for analog duplex mode and set the generator to
produce a 1200Hz sine wave with a peak deviation of 2.827kHz at the
receiver frequency.
3.10.2.2 In PCCT go to the Configure >Rx and Tx Manual window and set default
values for the Rx parameters as shown in Figure 3-15. Check the “Enable
Editing” boxes for entering parameters.
Figure 3-15 Configure Tx and Rx (Manual) Window