User's Manual
Table Of Contents
- 0 General
- 1 BASIS SETTINGS TO USE THIS RADAR
- 2 OPERATING INSTRUCTION
- 2.1 Radar Operation
- 2.2 Set to Operation
- 2.3 Display Organization and Submenu Structure
- 2.3.1 Sensitivity Controls
- 2.3.1.1 Gain and Clutter Processing
- 2.3.1.2 Tune
- 2.3.1.3 Gain
- 2.3.1.4 Sea
- 2.3.1.5 Rain Rate
- 2.3.1.6 Automatic Clutter Reduction
- 2.3.1.7 Filtering Rain Clouds FTC
- 2.3.1.8 Search and Rescue Transponder SART ON/OFF
- 2.3.1.9 Pulse Width Selection (only available in Master mode)
- 2.3.1.10 Interference Selection IR ON/OFF
- 2.3.1.11 Echo Expansion EXP. ON/OFF
- 2.3.2 Radar Video Displays
- 2.3.3 Radar Video Settings
- 2.3.4 Navigational Elements MAP, PIL, EBL and VRM
- 2.3.5 Cursor Information
- 2.3.6 Cursor in Park Position
- 2.3.7 Information Panel
- 2.3.1 Sensitivity Controls
- 2.4 Select Target Information TGT INFO
- 2.5 Target Menu
- 2.6 Zone Management
- 2.7 Function Menu
- 2.7.1 Select the Backlight Menu Brightness Control and Color Palette
- 2.7.2 Select T-SCE (ON/OFF)
- 2.7.3 Select Route (Option)
- 2.7.4 Select Zoom Menu
- 2.7.5 Select Sector Blanking (ON/OFF)
- 2.7.6 System Clear
- 2.7.7 Performance Monitor (PMU)
- 2.7.8 Magnetron Current
- 2.7.9 Test Alert
- 2.7.10 Senc Menu
- 2.7.11 Chart Info
- 2.8 Chart Radar Function
- 2.9 Select ARPA Trial Manoeuvre
- 2.10 Sea Scout (Option)
- 2.11 Alarm and Warning messages and handling
- 2.12 Working Around the Radar Antenna
- 3 Theory of Operation
- 4 Index
Synapsis Radar
with Nautoscan NX Pedestal
Operator Manual
Edition Sep 2015
2-3
4265.DOC020102
Pos. No.
Task
position is activated.
2
This button has no function.
3
This button is used for Pick up and drag operations and for
deleting ARPA or AIS targets and is used for the MFC Switch,
opening the Context Menu.
Normally this button is used on the Radar video to pick up a
symbol (e.g. EBL/VRM) and drag the symbol to a new position
within the Radar video using the trackball.
Press the left trackball button to release the symbol.
Select a ARPA/AIS target;
Place the cursor over an ARPA target and press the right
button.
In this case a context menu appears for approx. 10s. With
pressing the right button again target is selected.
Delete a ARPA/AIS target;
Place the cursor over an ARPA target and press the right
button. In this case a context menu appears for approx. 10s.
Select “Delete Target (ID …) and press the right button.
This action is not possible when the AIS INFO display was
selected before or when you are working with the ARPA ZONE
functions or another FUNCtion sub menu.
MFC switch and Context Menu;
Call up the MFC Switch, place the cursor over the “Raytheon
Anschütz” field and press the right button.