User's Manual
Table Of Contents
- 0 General
- 1 BASIS SETTINGS TO USE THIS RADAR
- 2 OPERATING INSTRUCTION
- 2.1 Radar Operation
- 2.2 Set to Operation
- 2.3 Display Organization and Submenu Structure
- 2.3.1 Sensitivity Controls
- 2.3.1.1 Gain and Clutter Processing
- 2.3.1.2 Tune
- 2.3.1.3 Gain
- 2.3.1.4 Sea
- 2.3.1.5 Rain Rate
- 2.3.1.6 Automatic Clutter Reduction
- 2.3.1.7 Filtering Rain Clouds FTC
- 2.3.1.8 Search and Rescue Transponder SART ON/OFF
- 2.3.1.9 Pulse Width Selection (only available in Master mode)
- 2.3.1.10 Interference Selection IR ON/OFF
- 2.3.1.11 Echo Expansion EXP. ON/OFF
- 2.3.2 Radar Video Displays
- 2.3.3 Radar Video Settings
- 2.3.4 Navigational Elements MAP, PIL, EBL and VRM
- 2.3.5 Cursor Information
- 2.3.6 Cursor in Park Position
- 2.3.7 Information Panel
- 2.3.1 Sensitivity Controls
- 2.4 Select Target Information TGT INFO
- 2.5 Target Menu
- 2.6 Zone Management
- 2.7 Function Menu
- 2.7.1 Select the Backlight Menu Brightness Control and Color Palette
- 2.7.2 Select T-SCE (ON/OFF)
- 2.7.3 Select Route (Option)
- 2.7.4 Select Zoom Menu
- 2.7.5 Select Sector Blanking (ON/OFF)
- 2.7.6 System Clear
- 2.7.7 Performance Monitor (PMU)
- 2.7.8 Magnetron Current
- 2.7.9 Test Alert
- 2.7.10 Senc Menu
- 2.7.11 Chart Info
- 2.8 Chart Radar Function
- 2.9 Select ARPA Trial Manoeuvre
- 2.10 Sea Scout (Option)
- 2.11 Alarm and Warning messages and handling
- 2.12 Working Around the Radar Antenna
- 3 Theory of Operation
- 4 Index
Synapsis Radar
with Nautoscan NX Pedestal
Operator Manual
Edition Sep 2015
1-7
4265.DOC020102
MICROWAVE RADIATION LEVELS
The maximum distances from the antenna at which radio frequency radiation
levels of 100 W/m2, 50 W/m2 and 10 W/m2 can be expected are included in
the following table and diagram.
The table and diagram shows simulated results for the 6” and 8“ X-Band Up
System (25 kW) and for the 12“ S-Band Up System (30 kW) for a none rotating
transmitting antenna (worst case scenario).
Table 1-2 Maximum distance from the antenna.
Radar System
Radiation
Density 100
W/m
2
Radiation
Density 50
W/m
2
Radiation
Density 10
W/m
2
Radiation
Density 6
W/m
2
6” X-Band;
Range
0,7 m
1,3 m
6,0 m
10m
8” X-Band;
Range
0,5 m
1,0 m
4,7 m
8m
12” S-Band;
Range
0,3 m
0,7 m
3,5 m
6m
X:0,26
Y:99,76
X:0,47
Y:99,28
X:0,47
Y:100,1
X:0,91
Y:50,14
X:4,69
Y:10,04
X:5,93
Y:10,08
X:0,62
Y:50,44
X:3,25
Y:10,07
X:1,23
Y:49,91