GUARD ZONE RING
Operator controls
Task
Step 1 Open the TGT menu.
Step 2 Open the CREATE ZONE menu.
Step 3 Open GUARD ZONE menu containing the options
SECTOR and RING.
Step 4 Open the GUARD ZONE RING menu.
Step 5 Apply the values. Pressing the COMMIT button
activates the GUARD ZONE RING in continuous line.
Result:
A range area with preset values for range START, range
END and own position appears on the PPI.
The range area is made up of two rings that can be
individually adjusted using editing marks.
There is an inner ring and an outer ring. When opening
the menu the circles are displayed with a dashed outline.
The rings can be changed by using the cursor and drag
and drop or by using the text line sliders.