User's Manual
Table Of Contents
- 0 General
- 1 BASIS SETTINGS TO USE THIS RADAR
- 2 OPERATING INSTRUCTION
- 2.1 Radar Operation
- 2.2 Set to Operation
- 2.3 Display Organization and Submenu Structure
- 2.3.1 Sensitivity Controls
- 2.3.1.1 Gain and Clutter Processing
- 2.3.1.2 Tune
- 2.3.1.3 Gain
- 2.3.1.4 Sea
- 2.3.1.5 Rain Rate
- 2.3.1.6 Automatic Clutter Reduction
- 2.3.1.7 Filtering Rain Clouds FTC
- 2.3.1.8 Search and Rescue Transponder SART ON/OFF
- 2.3.1.9 Pulse Width Selection (only available in Master mode)
- 2.3.1.10 Interference Selection IR ON/OFF
- 2.3.1.11 Echo Expansion EXP. ON/OFF
- 2.3.2 Radar Video Displays
- 2.3.3 Radar Video Settings
- 2.3.4 Navigational Elements MAP, PIL, EBL and VRM
- 2.3.5 Cursor Information
- 2.3.6 Cursor in Park Position
- 2.3.7 Information Panel
- 2.3.1 Sensitivity Controls
- 2.4 Select Target Information TGT INFO
- 2.5 Target Menu
- 2.6 Zone Management
- 2.7 Function Menu
- 2.7.1 Select the Backlight Menu Brightness Control and Color Palette
- 2.7.2 Select T-SCE (ON/OFF)
- 2.7.3 Select Route (Option)
- 2.7.4 Select Zoom Menu
- 2.7.5 Select Sector Blanking (ON/OFF)
- 2.7.6 System Clear
- 2.7.7 Performance Monitor (PMU)
- 2.7.8 Magnetron Current
- 2.7.9 Test Alert
- 2.7.10 Senc Menu
- 2.7.11 Chart Info
- 2.8 Chart Radar Function
- 2.9 Select ARPA Trial Manoeuvre
- 2.10 Sea Scout (Option)
- 2.11 Alarm and Warning messages and handling
- 2.12 Working Around the Radar Antenna
- 3 Theory of Operation
- 4 Index
Synapsis Radar
with Nautoscan NX Pedestal
Operator Manual
Edition July 2015
2-169
4265.DOC020102
2.6.1.1 Select ACQUISITION Zone Shape
The sequence of operations below can be used to select the acquisition zone
form SECTOR.
The Radar menu provides 3 types of acquisition zones;
• ACQUISITION ZONE SECTOR
Operator controls
Task
Step 1 Open the TGT menu.
Step 2 Open the CREATE ZONE menu.
Step 3 Open the ACQUISITION ZONE menu with the
options SECTOR, POLYGON, RING.
Step 4 Open the ACQUISITION ZONE SECTOR menu.
Step 5 Apply the values. Pressing the COMMIT button
activates the ACQUISITON ZONE SECTOR in continuous
line.
The BEARING values are relative to own ship.
Result:
A sector (displayed as a dashed outline) with preset
values appears in the direction of travel on the PPI.
The sector can be changed immediately using the sector
editing marks (1...4). These changes can be made directly
using the cursor (drag and drop (chapter 2.1.4.1)) or using
the text lines with slider functions for BEARING and
RANGE located in the ACQUISITION ZONE SECTOR
display field.
Subsequent changes can be introduced at any time.
Several SECTORS can be displayed on the PPI.