User's Manual Part 2
Operator Manual
Raytheon Marine GmbH
Germany
R
NSC 18
RADAR
2−81
3748DOC020102Edition: 14.JAN.2005
Result:
A range area with preset values for range START, range END and own position
appears in the radar video (see Figure: 2−42).
The range area is made up of two rings that can be individually adjusted using
editing marks.
There is an inner ring, which can be edited using drag and drop or the text line
(START) and an outer ring, which can likewise be edited using drag and drop or
the text line (END).
The default ring is small, as a suggestion for the anchor watch.
Using SLIDER function or
NUMERICAL softkeys
Using CURSOR function
− drag and drop −
Editing
markers
Figure: 2−42 ACQUISITION FORM RING
Apply values. Pressing the COMMIT button
activates the ACQUISITION ZONE RING
(continuous line).
Pick up and drag Set up
Sequence of actions