Temperature range -18 to 275°C (0 to 525°F)
Accuracy -1°C (30°F) to 275°C (525°F) ±2% or
±2°C (±3.5°F) whichever is greater
-18°C (0°F) to -1°C (30°F) ±3°C (±5°F)
Repeatability ±2% of reading, or ±2°C (±3°F),
whichever is greater
Response time 500 mSec, 95% response
Spectral response 7–18 µm
Emissivity* pre-set 0.95
Ambient operating range 0 to 50°C (32 to 120°F)
Relative humidity 10–95% RH noncondensing, @ up to
30°C (86°F)
Storage temperature -20° to 65°C (-4° to 150°F)
without battery
Weight / Dimensions 227 g (0.5 lb); 152 x 101 x 38 mm
(6 x 4 x 1.5 in)
Power 9V Alkaline or NiCd battery (included)
Battery life (Alkaline) 22 hrs (MT2) 12 hrs (MT4)
Laser Class II No (MT2) Yes (MT4)
Distance to Spot Size 8:1
Typical Distance to
Target (Spot) Up to 1.5m or 4 ft
Display Hold (7 seconds) ✓
LCD Backlit ✓
Temperature Display ºC or ºF selectable
Display Resolution 0.2ºC (0.5ºF)
Additional Options/Accessories Nylon Holster
*For more information on emissivity for unique applications visit
www.raytek.com/emissivity.htm
The MiniTemp is intended for close range targets,
measuring a minimum target area of 1 inch in
diameter out to a distance of approximately 8
inches, and has a 6 inch target measurement
area at 4 feet.
Optical Resolution
25mm @
200mm
50mm @
400mm
75mm @
600mm
1" @
8"
2" @
16"
3" @
24"
D
S
D:S = 8:1
Laser Sighting
Laser Point™ Single-point laser indicates the
approximate center of the target spot.
MT4 Model only
Worldwide
Headquarters
Raytek Corporation
1201 Shaffer Rd. PO Box 1820
Santa Cruz, CA 95061-1820 USA
Tel: 1 800 866 5478
1 831 458 1110
Fax: 1 831 425 4561
solutions@raytek.com
Raytek de Mexico, S.A. de C.V.
Puebla, Pue. Mexico
Tel: 52 222 230 4380
Fax: 52 222 230 4438
ventas@raytek.com.mx
Raytek China Company
Beijing, China
Tel: 86 10 6439 2255
Fax: 86 10 6437 0285
info@raytek.com.cn
Raytek Japan, Inc.
Osaka, Japan
Tel: 81 6 4390 5015
Fax: 81 6 4390 5016
info@raytekjapan.co.j
South American Headquarters
Raytek do Brasil
Sorocaba, SP Brasil
Tel: 55 15 32176046
Fax: 55 15 32175694
raytek@raytek.com.br
European Headquarters
Raytek GmbH
Berlin, Germany
Tel: 49 30 4 78 00 80
Fax: 49 30 4 71 02 51
raytek@raytek.de
Raytek UK Ltd.
Milton Keynes, United Kingdom
Tel: 44 1908 630800
Fax: 44 1908 630900
ukinfo@raytek.com
Raytek France
Palaiseau, France
Tel: 33 1 64 53 15 40
Fax: 33 1 64 53 15 44
info@raytek.fr
© 2002 Raytek Corporation (1-1101/ Rev. C) 7/2002
Raytek, the Raytek logo, MiniTempFS and the MiniTemp logo
are registered trademarks, and Laser Point is a trademark
of Raytek Corporation. Specifications subject to change
without notice.
Test Equipment Depot
99 Washington Street
Melrose, MA 02176-6024
www.testequipmentdepot.com
800-517-8431