User Manual

K? Inquire the current setting
This command is used to specify the baud rate of COM port
Modifiers Description
L* 1200bps
L# 2400bps
L0 4800bps
L1
9600bps
L2
(Default)
19200bps
L3 38400bps
L4 57600bps
L5 115200bps
L6 230.4Kbps
L7 460.8Kbps
L8 921.6Kbps
L
(Baud Rate
Control)
L? Inquire the current setting
This command is used to specify the parity bit setting of COM port
Modifiers Description
M0
(Default)
None Parity bit.
M1 Odd parity setting.
M2 Even parity setting
M
(Parity bits
setting)
M? Inquire the current setting
We can specifies the device a friendly name using 0 to 9, A to Z, a to z, space and –,
which are all valid characters. Note that "firs space or -, last space or isn’t permitted".
The default name is “Serial Adaptor”
Modifiers Description
N=xxxxx "xxxxx" is a character string, maxima length is 16
N
(Set
device
name)
N? Inquire the device name
This command is used to enable/disable auto-connection feature in master role. By the
way, it is used to online switch from command mode to data mode.
Note, it will cause a reboot when ATO0 or ATO1 take effect.
Modifiers Description
O
Online switch from command mode to data mode
O0
(Default)
Automatically connectting to a device which is assigned in “ATD” or any
available device if “ATD” was not assigned.
O1 Disable auto-connection feature, user should manually use “ATA”
command to connect a remote device.
O
(Auto connect
setting)
O? Inquire the current setting
This command specifies the PIN number. It control to off the PIN code authorization
that allow to establish a connection without PIN code.
Default PIN number is "1234"
Modifiers Description
P
(Set PIN code)
P=xxxx
(Default)
"xxxx" is 4~8 digit string