Operating instructions
34
Resets board to factory default settings.
Resets faults in the History File.
Change from Fahrenheit to Celsius.
SPA setpoint maximum adjustment.
POOL setpoint maximum adjustment.
SETdef – Default Settings
Refer  to  step  one  above  to  access  the  program
screen.  SETdef should appear on the screen. If not,
press  the  Mode button  until  SETdef appears  on  the
digital  display.    Press  and  hold  both  UP  and  DOWN
buttons  for  5-7  seconds  until  3  dashes  (---)  appear.
This operation resets the operating program to its fac-
tory default values. Both the POOL and SPA setpoints
will revert to 65°F (18.5°C) and  both POOL and SPA
maximum temperature settings will be 104°F (40.0°C).
Once this is done, reassemble the control panel.
RESfl – Reset Fault History
Refer  to  step  one  above  to  access  the  program
screen.    Press the Mode button  until  RESfl appears
on  the  digital  display.  Press  and  hold  both  UP  and
DOWN  buttons for  5-7 seconds  until  2  dashes (--)
appear. This operation resets  the Fault History file to
“0” and clears all the stored faults.  Once this is done,
reassemble the control panel.
Program Button
1) To  access  the  program  screen,  press  the  Mode
button  until  the  display  reads  OFF.  Remove  the
four  screws  holding  the  control  cover  on.  Swing
control panel down so the back side of the board
is visible (see page 31). Locate the Program Mode
button as  shown in  the figure on page 33.  Press
the  program  button  (5-7  seconds)  until  SETdef
a
ppears  on  the  digital  display.    Release  the  pro-
gram button.
2)  Press  the  Mode button  sequentially  until  the
desired program event is reached.  There are 5 dif-
ferent  events  that  can  be  programmed.  They
appear in the sequence listed below:
F/Cfff – Fahrenheit to Celsius
R
efer  to  step  one  above  to  access  the  program
screen.  Press the Mode button until F/Cfff appears on
t
he digital display. The digital display is capable of dis-
playing  Celsius  as  well  as  Fahrenheit  temperatures.
The UP or DOWN buttons will select “F” or “C” on the
temperature display. Choose the desired temperature
s
cale. Once this is done, reassemble the control panel.
SETspa 104 – SPA Set Point Maximum Adjustment
Refer  to  step  one  above  to  access  the  program
screen.   Press  the  Mode button  until SETspa 104
appears  on  the  digital  display.  Using  the  UP  and
DOWN buttons will change the Maximum Temperature
Setting to your desired value.  The control can be set
for a maximum of 107°F. Once this is done, reassem-
ble the control panel.
SETpool 104 – POOL Set Point Maximum Adjustment
Refer to  step one above  access into the  program
screen.    Press  the  Mode button  until  SETpool  104
appears  on  the  digital  display.  Using  the  UP  and
DOWN buttons will change the Maximum Temperature
Setting to your desired value.  The control can be set
for a maximum of 107°F. Once this is done, reassem-
ble the control panel.