Plumbing Diagrams
For systems with pumps of less than 1.5HP (1.1KW) (under 227 l/min) no external bypass
is required. Connections are 50mm pipe slip. Plumb the Heat Pump after the filter and
before the chlorinator.
Ensure chlorinators and chemical dosing units are installed AFTER the Heat
Pump.
For systems with pumps of 1.5HP (1.1KW) or greater (over 227 l/min) an external bypass
is required. Adjust the bypass valve to divert a minimum of 150 l/min through the Heat
Pump. Connections are 50mm pipe slip. Plumb the Heat Pump after the filter and before
any chlorinators.
Ensure chlorinators and chemical dosing units are installed AFTER the Heat
Pump.