User`s guide

1
Heaters
Great Plains Supply • Pool & Spa Products Dealer Catalog
Kansas City 913-492-1520 toll free 800-927-POOL (7665) fax 913-492-2631 or 800-927-4286
Houston 713-773-9000 toll free 800-769-POOL (7665) fax 713-773-9926
Section E
1
Coates Heaters/Hayward Heaters
Coates Inline and Compact Electric Spa Heaters
Stainless Steel tank, replaceable incoloy elements, close-differential
thermostat, manual reset hi-limit, and element on” light. Compact
spa heater also has built-in flow switch and on light. UL Listed,
1-1/2" male NPT connections.
CA1.5ILS 1.44 KW, Inline Spa Heater, 120v, 12 amp
CA6ILS 5.75 KW, Inline Spa Heater, 240v, 25 amp
CA12406ST 5.5 KW, Inline Spa Heater, 240v, 23 amp
CA12411ST 11.0 KW, Inline Spa Heater, 240v, 46 amp
Coates Commercial Electric Pool & Spa Heaters
Stainless Steel tank, replaceable incoloy elements, close-differential thermostat, manual reset hi-limit, and heavy duty contactor.
With built-in flow switch. UL Listed, two-year warranty on stainless steel tank.
** NOTE: These are Special Order Items. Allow minimum 10 working days.
240 Volt/Single Phase
CA12412CE 12 KW Electric Heater, 240v, 1 Phase, 51 amp
CA12415CE 15 KW Electric Heater, 240v, 1 Phase, 64 amp
CA12418CE 18 KW Electric Heater, 240v, 1 Phase, 77 amp
CA12424CPH 24 KW Electric Heater, 240v, 1 Phase, 102 amp
CA12430CPH 30 KW Electric Heater, 240v, 1 Phase, 128 amp
CA12436PHS-3 36 KW Electric Heater, 240v, 1 Phase, 153 amp
CA12445PHS 45 KW Electric Heater, 240v, 1 Phase, 191 amp
CA12454PHS-4 54 KW Electric Heater, 240v, 1 Phase, 225 amp
CA12457PHS 57 KW Electric Heater, 240v, 1 Phase, 238 amp
240 Volt/Three Phase
CA32412CE 12 KW Electric Heater, 240v, 3 Phase, 30 amp
CA32415CE 15 KW Electric Heater, 240v, 3 Phase, 37 amp
CA32418CE 18 KW Electric Heater, 240v, 3 Phase, 45 amp
CA32424CPH 24 KW Electric Heater, 240v, 3 Phase, 59 amp
CA32430CPH 30 KW Electric Heater, 240v, 3 Phase, 74 amp
CA32436PHS-3 36 KW Electric Heater, 240v, 3 Phase, 89 amp
CA32445PHS 45 KW Electric Heater, 240v, 3 Phase, 111 amp
CA32454PHS-4 54 KW Electric Heater, 240v, 3 Phase, 130 amp
CA32457PHS 57 KW Electric Heater, 240v, 3 Phase, 137 amp
NOTE: 208v and 480v available, POA.
Hayward H-Series Low NOx Heaters — Houston Only
Forced Draft System for Inground Pools and Spas meet the Texas Natural Resource Conservation
Commission Code for NOx Emissions standards. Features include a standard cupro nickel heat
exchanger with a low profile appearance, lighter weight design, independent left or right side
electric, water and gas connections plus 2" x 2-1/2" CPVC union connections. For Indoor/Outdoor use.
SPH250FDN 250,000 BTU Electronic Ignition Natural Gas Low Nox
SPH350FDN 350,000 BTU Electronic Ignition Natural Gas Low Nox
SPH400FDN 400,000 BTU Electronic Ignition Natural Gas Low Nox
SPH250FDP 250,000 BTU Electronic Ignition Propane Low Nox
SPH350FDP 350,000 BTU Electronic Ignition Propane Low Nox
SPH400FDP 400,000 BTU Electronic Ignition Propane Low Nox
Compact
Inline
46
Coates Heaters/Hayward Heaters
Kansas City 913-492-1520 toll free 800-927-POOL (7665) fax 913-492-2631 or 800-927-4286
Houston 713-773-9000 toll free 800-769-POOL (7665) fax 713-773-9926
Great Plains Supply • Pool & Spa Products 2008 Dealer Catalog
Heaters
Coates Inline and Compact Electric Spa Heaters
Stainless Steel tank, replaceable incoloy elements, close-
differential thermostat, manual reset hi-limit, and element on
light. Compact spa heater also has built-in flow switch and “on
light. UL Listed, 1-1/2" male NPT connections.
CA1.5ILS 1.44 KW, Inline Spa Heater, 120v, 12 amp
CA6ILS 5.75 KW, Inline Spa Heater, 240v, 25 amp
CA12406ST 5.5 KW, Inline Spa Heater, 240v, 23 amp
CA12411ST 11.0 KW, Inline Spa Heater, 240v, 46 amp
Coates Commercial Electric Pool & Spa Heaters
Stainless Steel tank, replaceable incoloy elements, close-differential thermostat, manual reset hi-limit, and heavy
duty contactor. With built-in flow switch. UL Listed, two-year warranty on stainless steel tank.
** NOTE: These are Special Order Items. Allow minimum 10 working days.
240 Volt/Single Phase
CA12412CE 12 KW Electric Heater, 240v, 1 Phase, 51 amp
CA12415CE 15 KW Electric Heater, 240v, 1 Phase, 64 amp
CA12418CE 18 KW Electric Heater, 240v, 1 Phase, 77 amp
CA12424CPH 24 KW Electric Heater, 240v, 1 Phase, 102 amp
CA12430CPH 30 KW Electric Heater, 240v, 1 Phase, 128 amp
CA12436PHS-3 36 KW Electric Heater, 240v, 1 Phase, 153 amp
CA12445PHS 45 KW Electric Heater, 240v, 1 Phase, 191 amp
CA12454PHS-4 54 KW Electric Heater, 240v, 1 Phase, 225 amp
CA12457PHS 57 KW Electric Heater, 240v, 1 Phase, 238 amp
240 Volt/Three Phase
CA32412CE 12 KW Electric Heater, 240v, 3 Phase, 30 amp
CA32415CE 15 KW Electric Heater, 240v, 3 Phase, 37 amp
CA32418CE 18 KW Electric Heater, 240v, 3 Phase, 45 amp
CA32424CPH 24 KW Electric Heater, 240v, 3 Phase, 59 amp
CA32430CPH 30 KW Electric Heater, 240v, 3 Phase, 74 amp
CA32436PHS-3 36 KW Electric Heater, 240v, 3 Phase, 89 amp
CA32445PHS 45 KW Electric Heater, 240v, 3 Phase, 111 amp
CA32454PHS-4 54 KW Electric Heater, 240v, 3 Phase, 130 amp
CA32457PHS 57 KW Electric Heater, 240v, 3 Phase, 137 amp
NOTE: 208v and 480v available, POA.
Hayward H-Series Low NOx Heaters Houston Only
Forced Draft System for Inground Pools and Spas meet the Texas Natural Resource Conservation
Commission Code for NOx Emissions standards. Features include a standard cupro nickel heat
exchanger with a low profile appearance, lighter weight design, independent left or right side
electric, water and gas connections plus 2" x 2-1/2" CPVC union connections. For
Indoor/Outdoor use.
SPH250FDN 250,000 BTU Electronic Ignition Natural Gas Low Nox
SPH350FDN 350,000 BTU Electronic Ignition Natural Gas Low Nox
SPH400FDN 400,000 BTU Electronic Ignition Natural Gas Low Nox
SPH250FDP 250,000 BTU Electronic Ignition Propane Low Nox
SPH350FDP 350,000 BTU Electronic Ignition Propane Low Nox
SPH400FDP 400,000 BTU Electronic Ignition Propane Low Nox
Compact
Inline
Electric Heater Sizing Guide
Model # K.W Voltage Phase Amps BTU/Hr
CA1.5L 1.44 120 1 12 4,915
CA12406ST 5.5 240 1 23 18.766
CA6IL 5.75 240 1 24 19,625
CA12411ST 11.0 240 1 46 37,530
Spa Water Volume
When the rate of recovery and the spa heat-up time are important,
or when the spa is used infrequently, determine the proper heating size
with the following calculations:
Capacity of Spa in Gallons = Length x Width x Avg. Depth x 7.5 (gal./cu.ft.)
Desired Temperature rise per Hour = deg.F
KW Required = Gallon Capacity x 8.3 (lbs./gal.) x temperature rise in deg. F/Hr
3413
Heating Capacity in Gallons per Hour (GPH)
Heater (KW) 5 deg.F/Hr 10 deg.F/Hr 15 deg.F/Hr 20 deg.F/Hr 25 deg.F/Hr
1.44 118gph 50gph 39gph
5.75 472gph 236gph 157gph 118gph 95gph
11 902gph 451gph 301gph 226gph 189gph