Operating instructions

7
INSTALLATION (Continued)
1
3. Install the right side outdoor conduit through the top 7/8” hole located on the right side of the heater.
See. Fig. 13. Note: You must first remove the 7/8” plug on the heater to install the hard conduit.
14. Wire the heater power lines along with the D-2 Power Vent power lines to the supply power per Fig. 15 for
010744 or 010745, and per Fig. 16 for 009832 or 009833. If the D-2 does not match the power supplied,
r
e-wire the blower for the correct voltage.
15. Reinstall the transformer cover. See Fig. 12.
1
6. Install the left side outdoor conduit through the top 7/8” hole located on the left side of the heater. See
Fig. 14. Note: You must first remove the 7/8” plug on the heater to install the conduit.
Power
Vent
Power
Supply
Fig. 13 Fig. 14
TO CONVERT FOR
240V OPERATION
FACTORY WIRED
120 VOLTS
D-2 POWER VENT
010744 & 010745
N
L1
TO CONVERT FOR
120V OPERATION
FACTORY WIRED
240 VOLTS
D-2 POWER VENT
009832 & 009833
Fig. 15 Fig. 16