Specifications

TM018 Raypak 131 Type A Pool & Spa Heaters REV: A
D.O.I: 8/04/2009
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
38
Fault Finding Tests 12 15
Test 12
Test 13
Using a multimeter on the AC voltage
scale, measure between the double violet
wire terminal and blue wire terminal on
relay 2.
The following result should be obtained:
24 Volts AC.
Using a multimeter on the AC voltage scale,
measure between the brown wire terminal
and blue wire terminal on relay 2.
The following result should be obtained:
24 Volts AC.
Test 14
Test 15
Disconnect wiring at 45ºC inlet high limit
and using a multimeter on the ohms scale,
measure between the two terminals on the
45ºC inlet high limit.
The following result should be obtained:
0 ohms (high limit contact closed).
Using a multimeter on the AC voltage scale,
measure between the bottom red wire
terminal and the blue wire terminal on relay
1.
The following result should be obtained:
24 Volts AC.