Specifications
D-2 Power Vent
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030, (805) 278-5300. Fax (800) 872-9725
www.raypak.com
Litho in U.S.A. ©2008-2011 Raypak, Inc. Catalog No. 6000.12F Effective: 02-15-13 Replaces: 05-01-11
For dimensions and technical specifications, see catalog number 6000.35.
In keeping with its policy of continuous progress and product improvement, Raypak reserves the right to make changes without notice.
D-2 Power Vent
Sometimes, equipment rooms or unusual venting configurations require the use of a power vent.
Being the heater experts, we have this option for you when the need may arise.
Through-the-Wall Capable
The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates under
a positive static pressure and prevents excessive condensate production in the vent. All sizes are
capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models
have a standard 4”-diameter exhaust connection.
Multi-Position
Using the Raypak-supplied adjustable 90° elbow, the flue gases may be discharged in any direc-
tion (see D-2 Power Vent manual for details). The D-2 Power Vent is also dual-voltage capable
(120/240 volt) and engineered for long life and smooth operation.
Model BTUH Input
206 199,500
266 266,000
336 332,500
406 399,000
Cabinet
• Outdoor top - (standard)
• Wind-resistant design
• Channels rainwater out
• Textured powder-coat finish
• Optional indoor top
Digital Controls
• Microprocessor-controlled
• Built-in diagnostics
• Back-lit LCD display
• Pool and spa settings
• Lexan cover- with snap closure
• Remote-compatible
• Flame strength meter
• Cycle and run time log
• Transformer output monitor
• Fault history-last 10
Burner Tray
• Easily removable
• Stainless steel burners
• Brass orifices
• Aluminized metals
• Stainless steel heat shield
• Spark-to-pilot ignition
• Soft-opening gas valve
Heat Exchanger
• Integral copper fin tube -
(standard)
• Automatic bypass
• Unitherm governor
• Polymer headers
• Stainless steel tube sheet
• Reversible for left-side
water connections.
• ASME - (optional)
• Cupro-nickel - (optional)
2” CPVC Connections
High Limits and Controls
• Mounted on the in/out header
Ceramic Fiber
Combustion Chamber
Non-Combustible Base
• Heater can be installed on a
combustible surface
120/240V
• Incoming power can be
• connected to the right or
• left side.
Optional D-2 Power Vent
Anything But Basic