Specifications

D-2 Power Vent
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030, (805) 278-5300. Fax (800) 872-9725
www.raypak.com
Litho in U.S.A. ©2008-2011 Raypak, Inc. Catalog No. 6000.12F Effective: 02-15-13 Replaces: 05-01-11
For dimensions and technical specifications, see catalog number 6000.35.
In keeping with its policy of continuous progress and product improvement, Raypak reserves the right to make changes without notice.
D-2 Power Vent
Sometimes, equipment rooms or unusual venting configurations require the use of a power vent.
Being the heater experts, we have this option for you when the need may arise.
Through-the-Wall Capable
The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates under
a positive static pressure and prevents excessive condensate production in the vent. All sizes are
capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models
have a standard 4”-diameter exhaust connection.
Multi-Position
Using the Raypak-supplied adjustable 90° elbow, the flue gases may be discharged in any direc-
tion (see D-2 Power Vent manual for details). The D-2 Power Vent is also dual-voltage capable
(120/240 volt) and engineered for long life and smooth operation.
Model BTUH Input
206 199,500
266 266,000
336 332,500
406 399,000
Cabinet
Outdoor top - (standard)
Wind-resistant design
Channels rainwater out
Textured powder-coat finish
Optional indoor top
Digital Controls
Microprocessor-controlled
Built-in diagnostics
Back-lit LCD display
Pool and spa settings
Lexan cover- with snap closure
Remote-compatible
Flame strength meter
Cycle and run time log
Transformer output monitor
Fault history-last 10
Burner Tray
Easily removable
Stainless steel burners
Brass orifices
Aluminized metals
Stainless steel heat shield
Spark-to-pilot ignition
Soft-opening gas valve
Heat Exchanger
Integral copper fin tube -
(standard)
Automatic bypass
Unitherm governor
Polymer headers
Stainless steel tube sheet
Reversible for left-side
water connections.
ASME - (optional)
Cupro-nickel - (optional)
2” CPVC Connections
High Limits and Controls
Mounted on the in/out header
Ceramic Fiber
Combustion Chamber
Non-Combustible Base
Heater can be installed on a
combustible surface
120/240V
Incoming power can be
connected to the right or
left side.
Optional D-2 Power Vent
Anything But Basic