Datasheet

North American Headquarters
601 Rayovac Drive
Madison, WI 53711
Telephone 1-800-331-4522
Internet www.rayovac.com
Marketing Data Sheet - Batteries
S6600137
Issue G
Memo No: 13509
Rayovac Stock Number:
675A
Name:
675A ZINC AIR HEARING AID
ENGINEERING DATA
ENGINEERING DATAENGINEERING DATA
ENGINEERING DATA:
Cell Chemistry: Zinc Air
Designation: ANSI/NEDA – 7003ZD, IEC – PR44
Recommended Use: Hearing Aid Instruments
Nominal Voltage: 1.4 volts
Approximate Weight: 1.77 grams (.06 oz)
Approximate Volume: .57 CU CM (.035 CU IN)
Standard Capacity: 320 hours – 620 OHM 12 hour/day
Discharge at 70°F (21°C) and 50% RH
To 1.1 volts.
High Rate Pulse: 75 hours – 8 mA background 24 mA 100 mS pulse
At 70°F (21° C) and 50% RH once/hour
16 hours/day to 1.05V.
Storage Loss at 70°
°°
°F (21°
°°
°C): Less than 5% in one year
With tab applied.
Environmental: Zinc Air batteries pose no threat to the environment
they pass the U.S. Environmental Protection
agency’s toxicity tests for Mercury, Cadmium and
Lead.
Rayovac Material Safety Data Sheets
Activation And Use: Remove and discard plastic tab covering air
Holes. Allow battery to stand for one minute to
insure proper activation. Battery compartment
must allow adequate oxygen supply to reach
air holes.
.197"-.213"
(5.0-5.4MM)
.443"-.457" DIA
(11.25-11.6MM)
AIR ACCESS HOLES
DIMENSIONS SHOWN ARE ANSI/IEC STANDARDS.
FOR ENGINEERING TOLERANCES CONTACT RAYOVAC.
This data is subject to change. Performance information is typical. Contents herein do not constitute a warranty.