Raynor Garage Doors 1101 E. River Road Dixon, Illinois 61021 www.raynor.com TM GARAGE DOOR OPENER Model 3265RGDM 1/2 HP For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation. ■ The door WILL NOT CLOSE unless the Protector System® is connected and properly aligned. ■ Periodic checks of the opener are required to ensure safe operation.
TABLE OF CONTENTS Introduction 2-5 Adjustment 23-25 Safety symbol and signal word review . . . . . . . . . . . . . . . 2 Adjust the travel limits . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . 3 Adjust the force. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Tools needed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Test the safety reversal system. . . . . . . . . . . . . . .
Preparing your garage door Before you begin: • Disable locks. To prevent possible SERIOUS INJURY or DEATH: • ALWAYS call a trained door systems technician if garage door binds, sticks or is out of balance. An unbalanced garage door may NOT reverse when required. • NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener. FINISHED CEILING SECTIONAL DOOR INSTALLATION Support bracket & fastening hardware is required. Slack in chain tension is normal See page 11. when garage door is closed.
Carton Inventory If anything is missing, carefully check the packing material. Parts may be stuck in the foam. Hardware for installation is also listed below. Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model purchased.
ASSEMBLY STEP 1 Attach the Rail to the Motor Unit To avoid SERIOUS damage to garage door opener, use ONLY those bolts/fasteners mounted in the top of the opener. To avoid installation difficulties, do not run the garage door opener until instructed to do so. • Remove the two washered bolts mounted in top of motor unit. • Position rail at a 45° angle to opener so one hole in rail and motor unit line up. USE ONLY THIS TYPE AND SIZE BOLT • Thread one of the washered bolts part way in.
ASSEMBLY STEP 3 Figure 1 Tighten the Chain Outer Nut Lock Washer Inner Nut To Tighten Outer Nut • Spin the inner nut and lock washer down the trolley threaded shaft, away from the trolley. To Tighten Inner Nut • To tighten the chain, turn outer nut in the direction shown (Figure 1). • When the chain is approximately 1/2" (13 mm) above the base of the rail at its midpoint, re-tighten the inner nut to secure the adjustment. Trolley Sprocket noise can result if chain is too loose.
INSTALLATION STEP 1 OPTIONAL CEILING MOUNT FOR HEADER BRACKET Unfinished Ceiling Determine the Header Bracket Location Header Wall 2x4 Vertical Centerline of Garage Door To prevent possible SERIOUS INJURY or DEATH: • Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might NOT reverse when required. DO NOT install header bracket over drywall. • Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
INSTALLATION STEP 2 Wall Mounting Holes Install the Header Bracket You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided).
INSTALLATION STEP 3 Header Wall Header Bracket Chain Pulley Bracket Attach the Rail to the Header Bracket • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring. • Position the rail bracket against the header bracket. • Align the bracket holes and join with a clevis pin as shown.
INSTALLATION STEP 5 Hang the Opener To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it securely to structural supports of the garage. Concrete anchors MUST be used if installing ANY brackets into masonry. Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener.
INSTALLATION STEP 6 Install the Door Control To prevent possible SERIOUS INJURY or DEATH from electrocution: • Be sure power is NOT connected BEFORE installing door control. • Connect ONLY to 24 VOLT low voltage wires. To prevent possible SERIOUS INJURY or DEATH from a closing garage door: • Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from ALL moving parts of door.
INSTALLATION STEP 7 Install the Light To prevent possible OVERHEATING of the endpanel or light socket: • DO NOT use short neck or specialty light bulbs. • DO NOT use halogen bulbs. Use ONLY incandescent. To prevent damage to the opener: • DO NOT use bulbs larger than 100W. • ONLY use A19 size bulbs. • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens.
INSTALLATION STEP 9 Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from electrocution or fire: • Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection. • Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes. • NEVER use an extension cord, 2-wire adapter, or change plug in ANY way to make it fit outlet. Be sure the opener is grounded.
INSTALLATION STEP 10 Install The Protector System® Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from a closing garage door: • Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled. • Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
INSTALLING THE BRACKETS Figure 1 Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows. DOOR TRACK MOUNT (RIGHT SIDE) Door Track Lip Indicator Light Garage door track installation (preferred): • Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door.
Figure 5 MOUNTING AND WIRING THE SAFETY REVERSING SENSORS Wing Nut 1/4"-20 Mounting: • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5). Carriage Bolt 1/4"-20x1/2" Lens • Finger tighten the wing nuts.
Connect to garage door opener: • Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener quick-connect terminals. Twist like colored wires together. Insert wires into quick-connect holes: white to white and white/black to grey (Figure 10). Connect Wire to Quick-Connect Terminals Finished Ceiling Figure 10 Bell Wire Bell Wire 1. Strip wire 7/16" (11 mm) 7/16" (11 mm) 2.
INSTALLATION STEP 11 Fasten the Door Bracket Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. Follow instructions which apply to your door type as illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel.
ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also. HARDWARE SHOWN ACTUAL SIZE • Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes. • Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws provided.
Figure 1 INSTALLATION STEP 12 Inner Trolley Connect Door Arm to Trolley Outer Trolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONLY Clevis Pin 5/16"x1" Ring Fastener Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" (5 cm) as shown in Figures 1, 2 and 3.
Figure 5 ALL ONE-PIECE DOORS CORRECT 1. Assemble the door arm, Figure 5: IMPORTANT: The groove on the straight door arm MUST face away from the curved door arm. INCORRECT Straight Door Arm • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). Straight Door Arm Curved Door Arm (Groove facing out) Curved Door Arm • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
ADJUSTMENT STEP 1 Adjust the UP and DOWN Travel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down. To operate the opener, press the Door Control push bar. Run the opener through a complete travel cycle.
ADJUSTMENT STEP 2 Adjust the Force Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Too much force on garage door will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to close garage door. • NEVER use force adjustments to compensate for a binding or sticking garage door.
ADJUSTMENT STEP 3 Test the Safety Reversal System Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.
OPERATION IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel. 4.
B) To operate one door using all three buttons on the hand-held remote: Using the Wall-Mounted Door Control THE MULTI-FUNCTION DOOR CONTROL Press the push button to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening. Light feature You may program the remote to open the door with the large button, close it with the middle button, and stop the door’s movement with the third button.
THE REMOTE CONTROL BATTERY CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause FORCE CONTROLS some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully. To prevent possible SERIOUS INJURY or DEATH: • NEVER allow small children near batteries. • If battery is swallowed, immediately notify doctor.
HAVING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. Bell Wire • Verify the safety sensors are properly installed, aligned and free of any obstructions. Refer to Installation Step 10: Install The Protector System®. • Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page.
Bell Wire Installed Safety Reversing Sensor Diagnostics Located On Motor Unit Safety Reversing Sensor LED or Diagnostic LED “Learn” Button Your garage door opener is programmed with self-diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below. Diagnostic Chart 1 FLASH Safety reversing sensors wire open (broken or disconnected).
PROGRAMMING NOTICE: If this SAFETY SIGNAL™ garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE “LEARN” BUTTON USING THE MULTI-FUNCTION DOOR CONTROL LOCK LIGHT 1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds. 2. Within 30 seconds, enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold the ENTER button. 3.
REPAIR PARTS Rail Assembly Parts 5 1 3 4 2 6 KEY NO. PART NO. DESCRIPTION 1 4A1008 Master link kit 2 41A4813 Chain pulley bracket 3 41A3489 Complete trolley assembly 4 1707LM One-piece rail - 7' (2.1 m) 5 41D3484 Full chain assembly 6 83A11-2 Rail grease NOT SHOWN Installation Parts KEY NO. 2 3 1 4 5 6 7 8 9 10 1708LM One-piece rail- 8' (2.4 m) 1710LM One-piece rail- 10' (3 m) PART NO.
Motor Unit Assembly Parts 17 1 2 3 5 16 5 9 15 4 6 7 10 13 8 18 6 Brown (Down) Contact Wire LIMIT SWITCH ASSEMBLY 14 12 Grey Wire Drive Gear 11 KEY NO. Center Limit (Up) Contact Contact Yellow Wire PART NO. DESCRIPTION KEY NO. PART NO.
ACCESSORIES 1702LM 373RGD Outside Quick Release: Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley. 59LM Includes visor clip. 374RGD Outside Keylock: Extension Brackets: 98LM Motion Detecting Door Control Panel: Multi-function door control with motion sensor that automatically turns opener lights on for 5 minutes when it detects a person entering the garage. Sensor can be easily deactivated when desired.
RAYNOR GARAGE DOORS SERVICE IS ON CALL HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly. INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE FIVE DAYS A WEEK. SIMPLY DIAL OUR TOLL FREE NUMBER: WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME 1-800-472-9667 • MODEL NUMBER HOURS: (Central Std.