Set Operation:
AT+ LOG =<debug_level,uart_num><CR>
+ok<CR>< LF><CR>< LF>
Parameters:
debug_level: UART debug level value, only show these log which debug level same or higher then this
setting.
0: Disable debug information output.
1XX: Output internal UART debug information which is same or higher then this set value.
uart_num: UART debug information output channel
0: UART0
1: UART1, uard rate 115200, with more system information output.
1.3.3.18. AT+FCLR
Function: Erase factory setting.
Format:
Query Operation:
AT+FCLR<CR>
+ok<CR><LF><CR><LF>
1.3.3.19. AT+FSET
Function: Copy User Parameters to Factory Default Parameters.
Format:
Query Operation:
AT+FSET<CR>
+ok=<status><CR><LF><CR><LF>
Parameters:
status: feedback operation status.
1.3.3.20. AT+UART
Function: Set/Query serial port parameters. Setting is valid after reset.
Format:
Query Operation:
AT+UART[=uart_num]<CR>
+ok=<baudrate,data_bits,stop_bit,parity,flowctrl><CR><LF><CR><LF>
Set Operation:
AT+UART=<baudrate,data_bits,stop_bit,parity,flowctrl>[,uart_num]<CR>
+ok<CR><LF><CR><LF>
Parameters:
uart_num: UART Channel, the default is UART0.
0: UART0 Channel
baudrate: baud rate
1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 380400, 460800, 921600
data_bits: data bit 8
stop_bits: stop bit 1
parity:
NONE
EVEN
ODD