ST80 Maxiview Operation and Setup Package Contents 1. Maxiview display head 2. Thumb nuts (2) 3. Threaded fixing studs (2) 4. White sun cover 5. SeaTalk cable 6. Installation template 7. Operation manual 8. Warranty card 9. Operation cue card 10.
2 ST80 Maxiview Operation and Setup Contents Chapter 1: Introduction ............................................................. 7 Quick Reference Guide ............................................... 7 Chapter 2: Operation ............................................................... 10 2.1 General ...................................................................... 10 Operating the Maxiview using the Remote Keypad .... 10 Keypad Beeps ...........................................................
3 ST80 Maxiview Operation and Setup 2.6 Navigate Chapter ........................................................ 22 Position Page ............................................................. 22 Course Over Ground (COG) & Bearing to Waypoint (BTW) ...................................................................... 22 Cross Track Error ...................................................... 23 Velocity Made Good (VMG) to Waypoint Page ......... 23 Waypoint Data Page .....................................
4 ST80 Maxiview Operation and Setup Chapter 3: Setup ...................................................................... 36 3.1 Entering Setup ............................................................ 36 Speed Chapter ........................................................... 37 Response Pages .................................................. 37 Trend Indicator Thresholds ................................. 38 Display Format ................................................... 40 Depth Chapter .....
ST80 Maxiview Operation and Setup 5 Chapter 4: CodeLock Security ................................................. 58 4.1 What is CodeLock? .................................................... 58 Master’s .................................................................... 58 Slave’s ...................................................................... 58 4.2 Analogue Display Heads ............................................. 59 Automatic CodeLock Systems ...................................
6 ST80 Maxiview Operation and Setup
7 ST80 Maxiview Operation and Setup Chapter 1: Introduction SP EE D max KNO ivie TS w D1580-1 The Maxiview is a large-screen LCD repeater capable of displaying single or multiple lines of alphanumeric SeaTalk data. With a display area measuring 126 x 70mm (5 x 2.7in), the Maxiview provides a clear and unambiguous display wherever you are on your boat. Unlike the other ST80 display heads, the Maxiview has a key-less facia.
8 ST80 Maxiview Operation and Setup Quick Reference Guide Press this key momentarily to cycle the available chapters. maxiview remote Press and hold for 1 second to select illumination adjustment. Additional key presses change the illumination setting. Press this key momentarily to cycle pages within the currently selected chapter. maxiview 12.5 FT 120oM Press and hold for 1 second to return to the previous page. remote Use the arrow keys to select another Maxiview display.
9 ST80 Maxiview Operation and Setup CHAPTERS PAGES SPEED CHAPTER SPEED DEPTH CHAPTER DEPTH SPEED OVER GROUND VMG TO WIND MINIMUM DEPTH DEPTH OFFSET LOG & TRIP AVERAGE SPEED MAXIMUM SPEED NP NP WIND CHAPTER HEADING CHAPTER APPARENT WIND SPEED APPARENT WIND ANGLE SAILING TRUE WIND SPEED SAILING TRUE WIND ANGLE MAGNETIC TRUE WIND ANGLE HEADING STEER COURSE OVER GROUND BEARING TO WAYPOINT TACK COURSE CROSS TRACK ERROR VMG TO WAYPOINT WAYPOINT DATA NP NP NAVIGATE CHAPTER POSITIO
10 ST80 Maxiview Operation and Setup Chapter 2: Operation 2.1 General The Maxiview operates around a chapter and page principle – chapters are independent sections: speed, depth, wind, etc., and pages data related to that chapter. When the Maxiview is powered up for the first time, the unit defaults to the SAIL configuration, unless a POWER configuration is received via SeaTalk (refer to the Masterview setup chapter).
11 ST80 Maxiview Operation and Setup 2.2 Speed Chapter Boat Speed Page This page displays your actual boat speed. maxiview SPEED KNOTS 10.5 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2469-1 • The speed units are the units currently on SeaTalk: KNOTS, MPH or KM/H.
12 ST80 Maxiview Operation and Setup Speed Over Ground (SOG) Page This page displays your current speed over the ground from GPS. maxiview SOG KNOTS 6.5 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2470-1 • The speed units can be: KNOTS, MPH or KM/H. Velocity Made Good (VMG) to Wind Page VMG to wind displays your boat speed through the water in the direction of true wind.
13 ST80 Maxiview Operation and Setup Log/Trip Page The Log/Trip page displays the total distance logged and a list of trips and their current status. maxiview LOG/ TRIP LOG TRIP TRIP TRIP TRIP TRIP 1 2 3 4 5 OFF OFF ON OFF ON NM 10000.5 1000.5 1102.5 20.20 0.00 50.85 remote Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. Press for 1 second to return to the previous page. D2472-1 • The units are those currently on SeaTalk: NM, SM or KM.
14 ST80 Maxiview Operation and Setup Average Speed This page displays the average boat speed for your current journey. maxiview SPEED AVG KNOTS 8.0 Press momentarily to advance to the next chapter. remote Press momentarily to advance to the next page. Press for 1 second to return to the previous page. D2473-1 • The units are those currently on SeaTalk: KNOTS, MPH or KM/H. • The word STOPPED is displayed if this feature is not running. • The maximum averaging period is 24 hours.
15 ST80 Maxiview Operation and Setup 2.3 Depth Chapter Depth Page The depth page displays the current depth available on SeaTalk. maxiview DEPTH FEET 32.5 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2475-1 • The displayed units are those currently on SeaTalk: FEET, FATHOMS or METRES.
16 ST80 Maxiview Operation and Setup Minimum Depth Page maxiview DEPTH MIN 9.2 FT remote Press momentarily to advance to the next chapter. Press for 1 second to return to the previous page. Press momentarily to advance to the next page. Press and hold these keys for 4 seconds to reset the minimum depth. D2476-1 • The units are: FEET, FATHOMS or METRES. • The time of the last echo is displayed in the 12 or 24 hour clock. This field is deactivated if time is not available.
17 ST80 Maxiview Operation and Setup 2.4 Wind Chapter Apparent Wind Speed page maxiview WIND APP KNOTS 20.0 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2478-1 • The units can be : KNOTS or M/SEC. Apparent Wind Angle Page maxiview WIND APP s STBD 090 remote Press momentarily to advance to the next chapter. Press momentarily to advance to the next page.
18 ST80 Maxiview Operation and Setup True Wind Speed Page (Relative to the Vessel) maxiview KNOTS 8.5 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2480-1 • The true wind units can be either: KNOTS or M/S. • This page is not available in POWER mode. True Wind Angle (Relative to the Vessel) maxiview PORT 096 Press momentarily to advance to the next chapter.
19 ST80 Maxiview Operation and Setup True Wind Angle (Referenced to the Compass) maxiview WNW 296 Press momentarily to advance to the next chapter. M Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2482-1 • This page is not available in POWER mode. • The angle can be either true (T) or magnetic (M). • An inter-cardinal/cardinal representation is also shown at the top right of the screen (e.g., WNW). 2.
20 ST80 Maxiview Operation and Setup Steering Page The steering page displays the current compass heading (unlocked mode) or the locked compass heading (locked mode). Note: For a detailed description of locked mode, please refer to a Masterview handbook. maxiview STEER UNLOCKED 136 Press momentarily to advance to the next chapter. T Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page.
21 ST80 Maxiview Operation and Setup Bearing to Waypoint (BTW) Page This page shows the magnetic or true bearing to a target waypoint. maxiview BTW TRUE 276 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2486-1 Tack Course Page This page displays the course for the next (opposite) tack in degrees true or magnetic. maxiview TRUE 326 Press momentarily to advance to the next chapter.
22 ST80 Maxiview Operation and Setup 2.6 Navigate Chapter Position Page maxiview POSITION N-E 050 49.10 002 49.10 remote Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. Press for 1 second to return to the previous page. D2488-1 • If position data is not available the fields are filled with dashes.
23 ST80 Maxiview Operation and Setup Cross Track Error The cross track error (XTE) page shows how far, in nautical miles (NM), statute miles (SM) or kilometres (KM), your vessel is from a planned route. maxiview XTE NM 0.34 Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. remote Press for 1 second to return to the previous page. D2490-1 • The arrows indicate the direction to steer to correct any error.
24 ST80 Maxiview Operation and Setup Waypoint Data Page This page displays any cross track error, the distance to a target waypoint (DTW), estimated time to arrival (ETA) and waypoint number. maxiview 010 DTW ETA 1.2 25.5 NM 01: 30: 15 remote Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. Press for 1 second to return to the previous page. D2492-1 • The arrows to the right or left of the XTE value indicate the direction to steer.
25 ST80 Maxiview Operation and Setup Date/Time/Tide Page This page displays the speed and direction of the tide and the local time. maxiview 12 JUNE 95 TIDE 6.5 KNOTS 130 TRUE remote Press momentarily to advance to the next chapter. Press momentarily to advance to the next page. Press for 1 second to return to the previous page. D2493-1 • Local time is a calculation based on a global offset . Please refer to the Masterview handbook for details.
26 ST80 Maxiview Operation and Setup 2.7 Race Timer Chapter Race Start Page This page duplicates race timer data from a Masterview instrument. There are just two operating modes: STOPPED and COUNTING DOWN/UP. maxiview RACE START 10:00 remote Press momentarily to advance to the next chapter. D2494-1 • The display shows minutes and seconds only. • When the timer reaches 00:00 the timer enters race mode (see below). maxiview RACE TIME 01:30 remote Press momentarily to advance to the next chapter.
27 ST80 Maxiview Operation and Setup 2.8 Multi-Line Multi-line chapters consist of up to 8 pages of user-defined pages. maxiview DEPTH 7.2 SPEED HEADING 2 FEET 6.7 KTS 120 M remote Press momentarily to advance to the next chapter. Press for 1 second to return to the previous page. Press momentarily to advance to the next page. Press these keys together momentarily to enter help/edit mode. D2496-1 • The multi-line page number is shown at the top-right of the screen.
28 ST80 Maxiview Operation and Setup Multi-line Setup maxiview DEPTH FEET SPEED 6.5 KTS 2 25.2 HEADING 120 M remote Press to change the current option to the previous option. Press to change the current option to next option. Press these keys together momentarily to switch between 1 and 2 line entries. Press and hold these keys for 4 seconds to delete the current multiline page. Press and hold these keys for 4 seconds to insert new multiline page before current.
29 ST80 Maxiview Operation and Setup List of Multi-line Selections The lines of data that can be selected are as follows: Line Data Line Data 1 Speed 17 Steer 2 Speed over ground 18 Course over ground 3 Velocity made good to wind 19 Tack course 4 Velocity made good over ground 20 Vessel latitude 5 Log 21 Vessel longitude 6 Trip 1 22 Cross track error 7 Average speed 23 Velocity made good to wayp’t 8 Depth 24 Waypoint number 9 Water temperature 25 Distance to waypoint
30 ST80 Maxiview Operation and Setup Multi-line Factory Defaults The factory defaults for the Multi-line pages are: Page Line Content 1 1 2 3 4 Speed Average speed Speed over ground Velocity made good to waypoint 2 1 2 Depth Water temperature 3 1 2 3 4 Heading Steer Course over ground Bearing to waypoint 4 1 2 3 True wind angle True wind speed Tack course 4 Beaufort 5 1 2 3 4 Waypoint number Cross track error Distance to waypoint Estimated time to arrival 6 1 2 Speed Depth 7 1 2 3
31 ST80 Maxiview Operation and Setup 2.9 Illumination There are two modes: local and system. Each of these modes has four possible settings: level 3 (brightest), level 2, level 1 and off. Local illumination is used to adjust the lighting of individual display heads — adjustments will not affect other display heads. System illumination controls the lighting of all display heads in system mode. maxiview LOCAL LAMPS 3 remote Press this key for 1 second from any page to open the illumination display.
32 ST80 Maxiview Operation and Setup Resetting the Contrast The display contrast can, during local or system illumination adjustment, be reset to the factory default by pressing the page key for 1 second. 2.10 Data Lost If a chapter that is dependent on a given quantity, e.g., speed, wind, depth, and this data is lost for more than 8 seconds, a warning screen is displayed until the data is restored. maxiview WARNING SPEED CHAPTER NOT AVAILABLE DATA LOST remote D2560-1 2.
33 ST80 Maxiview Operation and Setup • The dead reckoned screen is displayed providing data is available. • Fields where data is not available appear as dashes. • The elapsed time is displayed in minutes and seconds. • The displayed bearing and range is to the man in the water. Lat/Lon MOB maxiview MOBPOS 08:30 078 TRUE 1.2 NM remote Press this key momentarily to display dead reckoned information if available.
34 ST80 Maxiview Operation and Setup MOB Audible Alarm During an MOB condition, an audible alarm beeps 3 times every thirty seconds. Alarms The Maxiview can be set to respond to all the alarms in the following table or, alternatively, only those identified as specific.
35 ST80 Maxiview Operation and Setup The following table lists the alarm status once a silence/turn off key- sequence is performed.
36 ST80 Maxiview Operation & Setup Chapter 3: Setup This chapter describes how to set and adjust features in the setup menu. These include display formats, response levels for controlling the frequency of screen updates and the thresholds for trend indicators. 3.1 Entering Setup maxiview DEPTH f FEET 36.5 remote Press and hold these keys together for 2 seconds to display the user set-up screen. maxiview SET- UP PRESS " PAGE" TO CONTINUE...
37 ST80 Maxiview Operation & Setup Speed Chapter The following screen is displayed for 2 seconds when entering speed setup. The key sequences shown are only available during this period. maxiview SPEED SET-UP CHAP 1S FOR INSTRUMENT CHAPTER remote Press this key to advance to the next chapter. Press this key for 1 second to return to the instrument chapter. D2500-1 Response Pages Response is used to control the speed at which screens are updated. The response range is from 0 to 15.
38 ST80 Maxiview Operation & Setup There are two response pages: speed and VMG to wind. Speed response covers boat speed, speed over ground, velocity made good to waypoint and velocity made good over ground to waypoint. maxiview SPEED SET-UP KNOTS 16.5 RESPONSE S 07 F remote maxiview VMG SET-UP WIND 5.0 KNOTS RESPONSE S 10 F Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page.
39 ST80 Maxiview Operation & Setup maxiview SET-UP BOAT SPEED TREND THRESHOLD 0.80 KNOTS/ SEC remote maxiview SET-UP SOG TREND THRESHOLD 2.50 KNOTS/ SEC maxiview SET-UP VMG WIND TREND THRESHOLD 0.80 KNOTS/ SEC Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press this key for 1 second to return to the previous page. Press these keys together momentarily to decrease value by 0.01.
40 ST80 Maxiview Operation & Setup Display Format The display format can be set to either 1 or 2 decimal places. maxiview SET-UP BOAT SPEED DISPLAY FORMAT X.X X.XX ✓ ✗ remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press this key for 1 second to return to the previous page. Press these keys together momentarily to highlight X.X format. Press these keys together momentarily to highlight X.XX format.
41 ST80 Maxiview Operation & Setup Depth Response maxiview DEPTH SET-UP 20.5 FEET RESPONSE S 07 F remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press these keys together momentarily to decrease value by 1. Press these keys together momentarily to increase value by 1. Press this key for 1 second to return to the previous page. D2505-1 Trend Indicator Thresholds maxiview SET-UP DEPTH TREND THRESHOLD 2.
42 ST80 Maxiview Operation & Setup Depth Display Format maxiview SET-UP DEPTH SPEED DISPLAY FORMAT X X.X ✓ ✗ remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press this key for 1 second to return to the previous page. Press these keys together momentarily to highlight X format. Press these keys together momentarily to highlight X.X format. Press these keys together momentarily to select format.
43 ST80 Maxiview Operation & Setup Wind Speed Response maxiview SET-UP WIND SPEED KNOTS 5.0 RESPONSE S 07 F remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press these keys together momentarily to decrease value by 1. Press these keys together momentarily to increase value by 1. Press this key for 1 second to return to the previous page.
44 ST80 Maxiview Operation & Setup Display Format maxiview SET-UP WIND SPEED DISPLAY FORMAT X X.X ✓ ✗ remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press this key for 1 second to return to the previous page. Press these keys together momentarily to highlight X format. Press these keys together momentarily to highlight X.X format. Press these keys together momentarily to select format.
45 ST80 Maxiview Operation & Setup Editing Rights The editing rights chapter allows you to control the level of multiline page editing. The options are: edit all, edit pages and no editing. maxiview SET-UP MULTILINE EDIT ALL EDIT PAGES NO EDITING ✓ ✗ ✗ remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page. Press these keys together momentarily to highlight next option.
46 ST80 Maxiview Operation & Setup 3.2 Instrument Setup maxiview INSTRUMENT SET-UP CHAP 1S FOR MULTILINE CHAPTER remote Press this key for 1 second to return to the multiline chapter. Press this key to advance to the next chapter. D2514-1 Transducers Page This page lists all the transducers connected to SeaTalk. maxiview SET-UP TRANSDUCERS SPEED DEPTH WIND ✓ ✓ ✓ remote Press this key momentarily to advance to the next chapter. Press this key momentarily to advance to the next page.
47 ST80 Maxiview Operation & Setup Sail/Power/Custom Selection This page allows you to select whether chapters are custom selections or, alternatively, dictated by the sail or power boat settings. maxiview SET-UP SELECT TYPE SYSTEM CUSTOM ✓ ✗ remote Press this key momentarily to advance to the next chapter. Press this key for 1 second to return to the previous page. Press these keys together momentarily to highlight custom. Press these keys together momentarily to highlight system.
48 ST80 Maxiview Operation & Setup Custom This mode allows you to select any of the chapters from the following list: No. Chapter No. Chapter 1 Speed 5 Navigate 2 Depth 6 Timers 3 Wind 7 Multiline 4 Heading maxiview SET-UP CHAPTERS SPEED DEPTH WIND ✓ ✗ ✓ remote Press this key momentarily to return to speed calibration chapter. Press this key for 1 second to return to the selection page. Press this key momentarily to advance to the Title Page control.
49 ST80 Maxiview Operation & Setup Contents Setup In custom setup, contents setup is used to select or de-select pages within the highlighted chapter. maxiview SET-UP NAVIGATE CHAPTER OFF POSITION COG/ SOG ✗ ✓ ✓ remote Press these keys together momentarily to highlight the next page. Press this key momentarily to return to the chapter setup page. Press these keys together momentarily to turn the highlighted page ON/OFF. Press these keys together momentarily to highlight the previous page.
50 ST80 Maxiview Operation & Setup Title Control This is used to turn the chapter title pages, displayed for 2 seconds upon entry to a chapter, ON or OFF. maxiview SET-UP CHAPTER TITLE PAGES ON OFF ✓ ✗ remote Press this key momentarily to return to speed calibration chapter. Press this key momentarily to advance to the variation setup. Press this key for 1 second to return to the sail/power/custom selection page. Press these keys together momentarily to highlight ON.
51 ST80 Maxiview Operation & Setup Variation This page is used to enter the local variation to the nearest whole degree. maxiview SET-UP VARIATION 003 WEST remote Press this key momentarily to return to speed calibration chapter. Press this key momentarily to advance to the true/magnetic heading setup. Press these keys together momentarily to change value by 1 degree West. Press these keys together momentarily to change value by 1 degree East.
52 ST80 Maxiview Operation & Setup True/Magnetic Heading The true/magnetic heading page is used to select one of four options: local true, local magnetic, global true or global magnetic. maxiview SET-UP HEADING DISPLAY LOCAL TRUE LOCAL MAGNETIC GLOBAL TRUE ✗ ✓ ✗ remote Press this key momentarily to return to speed calibration chapter. Press this key momentarily to advance to lamp adjustment offset. Press this key for 1 second to return to the variation page.
53 ST80 Maxiview Operation & Setup Lamp Offset Adjustment This feature allows you to adjust the brightness of individual illumination levels to obtain the best setting for a particular location. maxiview SET-UP LAMP ADJSUTMENT LEVEL 2 MIN 32 MAX remote Press this key momentarily to advance to contrast adjustment. Press this key for 1 second to return to the previous page. Press these keys together momentarily to decrease value by 1. Press these keys together momentarily to increase value by 1.
54 ST80 Maxiview Operation & Setup Contrast Adjustment maxiview SET-UP CONTRAST ADJUSTMENT MIN 07 MAX remote Press this key momentarily to return to speed setup. Press this key momentarily to advance to LCD inversion control page. Press these keys together momentarily to decrease value by 1. Press these keys together momentarily to increase value by 1. Press this key for 1 second to return to the previous page.
55 ST80 Maxiview Operation & Setup LCD Inversion LCD inversion allows you to change the display to: • display black numbers and characters on a light background • or display light numbers and characters on a black background maxiview SET-UP DISPLAY NORMAL REVERSE ✓ ✗ remote Press this key momentarily to return to speed setup. Press this key momentarily to advance to alarm page control. Press this key for 1 second to return to contrast adjustment.
56 ST80 Maxiview Operation & Setup Alarm Control This page is used to define whether all or just specific alarms will be recognised by the Maxiview. maxiview SET-UP ENABLED ALARMS ALL SPECIFIC ✓ ✗ remote Press this key momentarily to return to speed setup. Press this key momentarily to return to transducers page. Press this key for 1 second to return to LCD inversion. Press these keys together momentarily to highlight specific. Press these keys together momentarily to highlight all.
57 ST80 Maxiview Operation & Setup 3.3 Quitting User Setup To quit setup, simply press the Chapter and Page keys together momentarily to display the following screen. maxiview SET-UP EXIT STORE SETTINGS CANCEL CHANGES ✗ ✓ remote If cancel is selected, press this key momentarily to exit without saving. If store is selected, press this key momentarily to exit and store new settings. Press these keys together momentarily to highlight cancel.
58 ST80 Maxiview Operation & Setup Chapter 4: CodeLock Security 4.1 What is CodeLock? • CodeLock is a personal four digit security code designed to protect your valuable equipment against theft. • CodeLock does not have to be switched on, but it’s there if you decide that you need it. • When CodeLock is switched on, the code number is stored in the memory of all CodeLock compatible equipment on the same bus. • A CodeLocked piece of equipment, if stolen, cannot be used without the correct code number.
ST80 Maxiview Operation & Setup 59 4.2 Analogue Display Heads Automatic CodeLock Systems In an automatically transmitted CodeLock system, the Maxiview reads the code number and starts-up automatically without any user input. Manual CodeLock System In a manually transmitted CodeLock system, the code number is entered via the keypad of any master display head. This code is then sent to all compatible equipment on the same SeaTalk bus.
60 ST80 Maxiview Operation & Setup Chapter 5: Problem Solving 5.1 Problem Solving Display is blank • Make sure that the power supply is connected. • Check the fuse or circuit breaker. • Make sure that the SeaTalk cables are not damaged. • Check the contrast and illumination settings • Faulty LCD module. No exchange of information between SeaTalk instruments • Make sure that the cables are attached securely. • If the problem persists, disconnect your instruments one by one to isolate the faulty unit.
ST80 Maxiview Operation & Setup 61 Chapter 6: EMC and Servicing Guidelines 6.1 Important information All Autohelm equipment and accessories are designed to the best industry standards for use in the leisure marine environment. Their design and manufacture conforms to the appropriate Electromagnetic Compatibility (EMC) standards, but good installation is required to ensure that performance is not compromised.
62 ST80 Maxiview Operation & Setup 6.3 Check Before Going to Sea • Always check the installation before going to sea to make sure that it is not affected by radio transmissions, engine starting etc. • In some installations, it may not be possible to prevent the equipment from being affected by external influences. In general this will not damage the equipment but can lead to it resetting, or momentarily may result in faulty operation. 6.
63 ST80 Maxiview Operation & Setup Chapter 7: Specification Dimensions: 110 x 114.5 x 18.25mm (4.33 x 4.5 x 0.
64 ST80 Maxiview Operation & Setup
65 ST80 Maxiview Operation & Setup Index A G Alarm Control 56 Alarms 34 Apparent Wind Angle Page 17 Apparent Wind Speed page 17 Audible Alarms 35 Automatic CodeLock Systems 59 Average Speed 14 Gaining Control of the Maxiview H Heading Chapter 19 Heading Page 19 Help/Setup Page 27 I B Bearing to Waypoint (BTW) Page Boat Speed Page 11 21 Illumination 31 Incomplete MOB Data Instrument Setup 46 C K CodeLock Security 58 Contents Setup 49 Contrast Adjustment 54 Course Over Ground (COG) & Bearing to W
66 ST80 Maxiview Operation & Setup O V Operating the Maxiview using the Remote Keypad 10 Variation 51 Velocity Made Good (VMG) to Waypoint Page 23 Velocity Made Good (VMG) to Wind Page 12 P Problem Solving 60 W Q Quitting User Setup 57 R Race Start Page 26 Race Timer Chapter 26 Resetting the Contrast 32 Response Pages 37 Waypoint Data Page 24 What is CodeLock? 58 Wind Angle Response 43 Wind Chapter 17, 42 Wind Speed Response 43 S Sail/Power/Custom Selection 47 Servicing and Safety 62 Setup 36 S